54
Settings “temperature drop”
only for “automatic” mode
Display
Action
Description
settings
standby
max. power
temp drop
3
on
2
°C
or
Temperature drop describes the switching difference
between the set room temperature and switching
back on of the appliance in standby operation.
Adjustable temperature range: 1°C - 6°C
Factory setting: 2°C
Select the temperature with (ENTER) (the value
flashes), set the value with ↓ or ↑ and confirm with
(ENTER).
Settings “temperature off”
only for “automatic” mode
Display
Action
Description
settings
standby
temp drop
on
2 °C
temp. off
1
°C
or
In the “temperature off” menu the switch off hyster-
esis will be set at which the appliance in standby
mode switched off.
Adjustable temperature range: 1°C - 3°C
Factory setting: 1°C
Select the temperature with (ENTER) (the value
flashes), set the value with ↓ or ↑ and confirm with
(ENTER).
Example:
Set room temperature:.. 20°C
Set temperature drop:..... 2°C
Set temperature off: ........ 1°C
Appliance goes into standby at: 20°C + 1°C = 21°C
Appliance reignites at: ...............20°C – 2°C = 18°C