Defects
If your storage heater malfunctions, and the display does not show any
error messages, please first check the following:
•
Appliance failed to charge:
-
If the target charge level rotary knob on the appliance set to zero?
-
Are the fuses on the current distribution board loose or defective?
•
Appliance fails to discharge via the fan:
-
Has the temperature shown on the display been set using the target
room temperature rotary knob to a lower value than the current room
temperature?
-
Has the fan been cleared? If the green LED control light is not on, the
fan has not been cleared.
-
Are the fuses for the fan circuit on the current distribution board loose
or defective?
Error messages
Faults caused by the electronic control system will be shown in the LCD
display, alternating with the standard display (fig.32). In addition, the back-
lighting facility will be activated to alert the operator to the error..
The following error messages may be displayed:
Fig.32
Display Description
Error 1
Error when measuring the room temperature;
room temperature sensor or its cable defective
Error 2
Error when measuring the core temperature;
core sensor or its cable defective
Error 3
Defective charge process;
core temperature too low at the end of the charge process,
or fell too steeply during charging
Error 5
Temperature on the control module or
operating element too high
Error 7
Clock not OK
1)
Error 8
Internal error in the control unit
Error 9
Internal error in the operating element
Table 4
1)
The error detection setting in respect of the time is highly sensitive, which means that even very minor irregulari-
ties may result in an error message. Before calling customer service, access the Day/Time menu and set the
time. Only if this error message recurs repeatedly is the error serious enough to call customer service.
Your fitter will naturally be available to assist you in the event of faults.