Y108540-8
Service Manual
3-3
3.3
MAINBOARD/OPERATOR-CLIENT DISPLAY ASSY DISASSEMBLY/REASSEMBLY
• Remove the printer case from the machine frame as explained in the related section of this chapter, lift it gently
and turn it to one side. Be careful to not detach the connection cables.
• From the mainboard/operator-client display assy, disconnect the printer assy flat cable connectors (1), the
transformer cable connector (2), the memory backup battery power supply cable connector (3), the keypad flat
cable connectors (4), the USB port connector (5) and the serial port connector (6).
• Remove the six screws (7) that secure the mainboard/operator-client display assy and then gently lift the assy
from its support.
Reassembly
• To reassemble the mainboard/operator-client display assy, proceed with the disassembly procedures in reverse
order. When reconnecting the different cables, make sure that you position them in correspondence with the
reference marks on the connectors of the main board.
Fig. 3-4
3
1
2
7
7
5
6
4