II. End Raise Control
The deck end raise, which controls how far the deck can be sloped relative to being flat, can also be
set from 0 to 100. At zero percent end raise, the deck will be flat. At >0% the deck will be negatively
sloped from the feeder to the discharge.
Figure 31: Deck End Raise Positions
III. Deck Speed Control
The Deck Speed parameter controls how fast the deck eccentric is shaking the deck. On a Gravity
Table it can set from 450 to 600.
IV. Actuators
The actuators are like the fans in that they open all the way at 100% and close all the way at 0%.
The feeder gate will close all the way when the machine is turned off.
V. Starting the Machine
Notice also that there is a button on the screen that says Start. This same button is also found on the
Main screen and on the other two screens accessible from the Main Settings screen, the Deck and
Fan Screens. When pressed, and the machine is not faulted, the button will turn from green to red,
and instead of saying start, it will say Stop. When this happens the machine will start and
automatically move to the correct position and ramp up to the correct fan speeds as given in the
parameters. Hence the reason it is called Automatic mode. The whole machine responds to the
settings on this screen almost very quickly.
VI. Faults
The one thing to watch out for when running the machine in automatic mode is faults. Faults occur
when the machine doesn’t reach the desired position of the deck in 60 seconds, when the VFD’s that
Содержание Platinum Series
Страница 9: ...8 This Page Intentionally Left Blank...
Страница 19: ...18 Figure 10 Air flow example Voyager 1050 Figure 11 Effects of Air Speed on Separation...
Страница 23: ...22 Figure 15 PowerFlex 525 Variable Frequency Drive...
Страница 28: ...27...
Страница 31: ...30 Figure 23 Login to Actuator Calibrate Figure 24 Actuator Calibration Screens...
Страница 61: ......