31
When you come to the actuator screen, there are 4 possible sets of actuators you might have. On a
Maxi-Cap or Voyager, there are 4 low gates, which are the discharge gates and the feeders, and then
there are four high gates including the rock trap and other gates along the deck. On some models
none of these have been automated yet. If you have a Maxi-Cap platinum retrofit machine, there will
be several dampers available as well. Which actuators you are calibrating is controlled by the button
in the lower right that says either low gates, high gates, dampers 1, or dampers 2. Different gates
will be visible depending on what that button says. Pushing it will control which setting it is on and
which actuators are visible. Consider Figure 24.
All of the actuators are controlled exactly like the deck positions were. Press the up arrow to extend
the actuator, and the down arrow to retract it. Record the highest voltage value in the right box, and
the lowest value in the left box.