5 - TECHNICAL DATA
40
Design Specifications and Capacities*
Maestro Pro 12 HP
Model Number
01925
Voltage (min 109, max 127)
AC Volts/Phase/Hertz
115-1-60
Rated Capacity for both Cooling & Heating (1)
BTUh/Kw
8,150/2.4
Maximum Capacity for both Cooling and Heating (2)
BTUh/Kw
11,600/3.4
Rated Power Consumption - Cooling Mode
Watts
830
Rated Power Consumption - Heating Mode
Watts
850
Combined Energy Efficiency Ratio - Cooling
CEER
9.74
Combined Energy Efficiency Ratio - Heating
CEER
9.79
Coefficient of Performance
COP
9.90
Compressor
Rated Load Amps
Type
R.L.A.
Rotary Inverter
4.9
Indoor Fan
Speeds
Full Load Amps
Type
# of speeds
F.L.A.
PSC
Variable
.33
Indoor Air Volume
(Cooling Mode)
CFM/CMM (H,M,L)
830-660-590 / 23.5-18.7-16.7
Indoor Air Volume (Heating Mode)
CFM/CMM (H,M,L)
830-660-590 / 23.5-18.7-16.7
Outdoor Fan Speeds
# of speeds
Variable
Intake/Exhaust Hole Diameter (3)
Inches/mm (each)
8/202
Maximum Remote-Control Range
Feet/Meters
26/8
Dimensions (without packaging)
W-H-D inches/mm
35.5 x 20.4 x 8.5 / 902 x 610 x 216
Dimensions (with packaging)
W-H-D inches/mm
38.6 x 24 x 13.0 / 980 x 610 x 330
Weight (without packaging)
lbs/kg
86/39
Weight (with packaging)
lbs/kg
93/42.2
Sound Level (4)
DBA min-max
32 - 43
Refrigerant
ASHRAE #
R-410A
Refrigerant Factory Charge
loz/gr
20.5/581
Design Condition Parameters*
Dolceclima Air Pro 14 HP
Indoor
Temperature
Maximum Operating Temperature in Cooling Mode
°F/°C
DB 95°F/35°C - WB 75°F/24°C
Minimum Operating Temperature in Cooling Mode
°F/°C
DB 64°F/18°C
Maximum Operating Temperature in Heating Mode
°F/°C
DB 81°F/27°C
Minimum Operating Temperature in Heating Mode
°F/°C
-
Outdoor
Temperature
Maximum Operating Temperature in Cooling Mode
°F/°C
DB 109°F/43°C - WB 90°F/32°C
Minimum Operating Temperature in Cooling Mode
°F/°C
DB 14°F/-10°C
Maximum Operating Temperature in Heating Mode
°F/°C
DB 75°F/24°C - WB 64°F/18°C
Minimum Operating Temperature in Heating Mode
°F/°C
DB 5°F/-15°C
* Values may change if models are revised. Always use the latest publication date for any literature.
(1) Test condition: Data refers to conditions and parameters as required by DOE requirements governing this product type.
HEATING MODE: Outdoor Ambient Temperature DB 45°F/7°C WB 43°F/6°C; Indoor Ambient DB 68°F/20°C - WB 59°F/15°C
COOLING MODE: Outdoor Ambient Temperature DB 95°F/35°C WB 75°F/24°C; Indoor Ambient DB 81°F/27°C - WB 66°F/19°C
(2) Maximum capacity achieved with Power Pro Boost inverter technology
(3) To achieve full capacity and efficiency 8”(202mm) diameter pipes are recommended. Alternately, 6.4”(262mm) diameter pipes can be
used however there is a corresponding loss to capacity and efficiency which can vary based on the specific application.
(4) Test conditions for sound ratings are conducted as per DOA rating conditions, conducted in a sound chamber performed at a distance
of 3.3 feet (1 meter). Minimum sound pressure values are rated in fan mode only.
(5) STC and OITC calculated by an independent 3rd party in accordance with ASHRAE standards.
Sound
Transmission Class
(
5
)
STC
36
Outdoor Indoor Transmission Class
(5)
OITC
25
Содержание Maestro Pro 01925
Страница 1: ...12 HP Model 01925 INVERTER ...
Страница 9: ...m Y 4 5 3 9 ...
Страница 10: ...min 12 300mm 8 9 B N ø 3 8 mm 6 h h 7 6 10 ...
Страница 12: ...15 19 17 16 20 18 F E E E 12 1 4 6 mm ...
Страница 13: ...22 23 A A B B 21 W 13 ...
Страница 14: ...h h L L 26 28 24 29 25 L L 27 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a A A A A A 1c 14 ...
Страница 15: ...34 32 33 35 J1 J2 J1 J2 X3 X4 30 31 X1 X2 X2 15 ...
Страница 16: ...41 39 40 F 3 F F2 F1 F F2 F2 F1 F1 26 8m 38 36 37 10 7 16 3 2 80mm ...
Страница 17: ...43 3 3 42 F 44 45 6 6a 17 min 5qts 4 8L ...