The unit must be installed on an outside wall!
After determining the best place for installation as described above, check for
the absence of other structures or systems (beams, piers, pipes, wires, etc.) at
the points where the holes are to be drilled, which would prevent drilling the
holes required to install the unit. Check again to make sure there are no
obstacles to air circulation through the holes to be drilled due to plants and their
leaves, slats or panelling, blinds, gratings or grids too dense, etc.).
2.4 - UNIT ASSEMBLY
The maximum allowed length of the pipes is 118" (3m), the pipes must be internally smooth,
with a diameter equal to 8" (202mm) or 6.5" (165mm) and bends in the pipe are not permitted.
The installer must use the grilles provided, or 3rd party grills that match the volume and
velocity of the original.
2.4.1 - Drilling the wall
Drill
two holes either 8"
(202mm)
or 6.5"
(165mm)
in diameter in the wall as indicated
on
the template.
The 8"
(202mm)
holes will ensure best performance a
s well as
the lowest sound level.
•
Drill the wall using the proper tools to facilitate your job and prevent excess damage or disturbance
to
your wall surfaces, both inside and outside. the best tools for drilling large holes in concrete or brick
walls are special drill bits called core borers with very high twisting torque and adjustable rotating
speed depending on the diameter of the hole to be drilled.
21
Drill the foregoing holes tilted slightly downwards to prevent water from being fed back through
the ducts (fig. 5).
Most of the removed material is expelled outwards, therefore make sure that it
does not hit any person or object when it falls out. In order to avoid as much
as possible outer plaster breaking, it is necessary to proceed carefully with
the last part of hole execution, decreasing pressure on core borers.
•
Drill the holes, previously marked
related to the fixing brackets (fig. 6).
The manufacturer will not be held liable for any underestimates made in the
structural consistency of the anchor prepared by the installer. Therefore, pay
attention to the foregoing operation that could cause serious injury/damage to
people/property if carried out incorrectly.
To properly dispose of condensate the installer must either
drill a
5/8" (16mm)
hole
through the wall in the position shown on the template
or provide means to dispose of
the condensate through the bottom of the unit into a drain or condensate pump.
Note:
To avoid frozen lines leading to unit high water alarms, if outdoor temperatures
can be expected to drop below 32ºF (0ºC) for any extended time interval the
condensate line should not be installed through the wall to the outside.
Содержание Maestro Pro 01925
Страница 1: ...12 HP Model 01925 INVERTER ...
Страница 9: ...m Y 4 5 3 9 ...
Страница 10: ...min 12 300mm 8 9 B N ø 3 8 mm 6 h h 7 6 10 ...
Страница 12: ...15 19 17 16 20 18 F E E E 12 1 4 6 mm ...
Страница 13: ...22 23 A A B B 21 W 13 ...
Страница 14: ...h h L L 26 28 24 29 25 L L 27 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a A A A A A 1c 14 ...
Страница 15: ...34 32 33 35 J1 J2 J1 J2 X3 X4 30 31 X1 X2 X2 15 ...
Страница 16: ...41 39 40 F 3 F F2 F1 F F2 F2 F1 F1 26 8m 38 36 37 10 7 16 3 2 80mm ...
Страница 17: ...43 3 3 42 F 44 45 6 6a 17 min 5qts 4 8L ...