12.3 Timer ON setting from the display unit:
o
Switch ON the unit and select by SW2, SW3, SW4 and SW5
the working mode, set temperature and fan speed the unit will apply
when it will switch ON;
o
Switch the unit to standby mode by pressing SW1.
o
Press SW6 to set the desired time delay (from 1 to 12 hours) after which the unit will switch
ON (starting from timer confirmation). S4 is switched ON and S2=’h’, S3 starts to blink,
symbols S6 to S13 show for 5 seconds (blinking) the setting the unit will apply when it will
switch ON and D1-D2 show (blinking) the previous selected delay time value or the preset
one (6h) if no other timer confirmations have occurred before;
o
Press SW4 or SW5 to increase/decrease the delay time value shown by D1 and D2. If no key
operations occur for more than 5 seconds the timer setting function ends.
o
Confirm the desired delay time by pressing SW6. The LED L2 is switched OFF, S3 stops to
blink and remain switched ON, and D1 - D2 show the delay countdown to the switch ON
operation. Symbols S6 to S13 show for 5 seconds the setting the unit will apply when it will
switch ON;
o
In order to cancel the delayed switch ON action, press the SW6 button. D1 and D2 will show
(together with S2=’h’, S3 and S4) for 5 seconds (in blinking mode) and then the
unit will switch to standby mode (L1 OFF and L2 ON).
o
When the delay time set has elapsed, the unit switches ON with previously selected settings.
All the timer symbols (S2, S3 and S4) on the local interface disappear.
12.4 Timer OFF setting from the display unit:
o
With the unit in any working mode (except standby), press SW6 to set the desired time delay
(from 1 to 12 hours) after which the unit will switch OFF (starting from timer confirmation).
S4 is switched ON, S2=’h’, S5 starts to blink and D1-D2 show (blinking) the previous
selected delay time value or the preset one (6h) if no other timer confirmations have occurred
before;
o
Press SW4 or SW5 to increase/decrease the delay time value shown by
D1 and D2. If no key operations occur for more than 5 seconds the timer setting function
ends.
o
Confirm the desired delay time by pressing SW6. S5 stops to blink and is switched ON, S2 is
switched OFF whereas D1 - D2 change back to show the Tset (only in cooling mode,
otherwise ‘ ‘ );
o
By pressing SW6, S2, D1 and D2 shows for 5 seconds in blinking mode the remaining delay
countdown to the switch OFF operation, and then restores the previous visualization.
In order to cancel the delayed switch OFF action, press the SW6 button. During the remaining delay
countdown visualization, press once more time the SW6 button. D1 and D2 will show
(together with S2=’h’, S4 and S5, all blinking) for 5 seconds, then S4 and S5 will be switched OFF
and D1 – D2 and S2 will restore the previous visualization
Содержание ELLISSE HP
Страница 1: ...ELLISSE HP 1 Technical Specification ...
Страница 3: ...3 Remote control 3 1 Remote control display ...
Страница 13: ...15 Wiring diagram ...
Страница 14: ...16 Sensor data ...
Страница 15: ......