User Manual LR-16F
OMEN-16F-202012
8
Figure 9 Schematic diagram of vertical angle definition
7.
Format of data package
LR-16F enables laser point cloud data transmission. Please refer to the following for the
analysis of lidar point cloud data.
The information transmission between the LR-16F and the computer follows the UDP
standard network protocol. The data package adopts the Little-endian format, with the low
byte in the front and the high byte in the back.
7.1.
Communication protocol-data package
7.1.1.
Overview
The specific information stored in the data package is the distance value, calibrated
reflectivity, azimuth angle, time stamp and factory mark returned by the laser. The factory
mark contains sensor model and return mode information.
The total length of the data package is 1248 bytes, including 42 bytes for the header file,
1200 bytes for the laser returned data, 4 bytes for the time stamp, and 2 bytes for the factory
mark. The basic structure is shown in the figure below.