11.3 Heating circuit group
B
Bu
urrn
nss
Switch off the complete heating system 6 hours in adv-
ance and secure it to prevent restarting before com-
mencing work on the system.
L
Le
ea
ak
kss
All hydraulic connections must be properly tightened
and sealed during installation.
The heating circuit group consists off:
1
Return HC
2
Flow HC
3
Boiler controlled pump HC
4
Mixer HC
1 heating circuit
2 heating circuits
(with distributor)
3 heating circuits
(with distributor, wall mounted)
Technical data
Dimensions between axes
3.54”
Connection producer
1” external thread flat sealing
Connection consumer
1” internal thread
Mounting dimensions:
Height/width/depth
11.8 / 7.5 / 5.9”
Recommendation / performance limits:
for floor heating
max. 18 kW per heating circuits
for radiator heating
max. 32 kW per heating circuits
Flow capacity
2–8 l/h
Pump
Wilo Yonos Para RSTG 15/7,5
Installation Manual PELLEMATIC® SmartXS
Содержание PELLEMATIC SmartXS
Страница 28: ...Dismantling sequence of the housing parts PE 607 USA_FA 2 1 28 Dismantling of the housing parts ...
Страница 29: ...Dismantling of the housing parts 29 Installation Manual PELLEMATIC SmartXS ...
Страница 30: ...PE 607 USA_FA 2 1 30 Dismantling of the housing parts ...
Страница 45: ...Suggested piping arrangement for combined operation 45 Installation Manual PELLEMATIC SmartXS ...
Страница 49: ...Wiring diagrams 49 Installation Manual PELLEMATIC SmartXS ...
Страница 50: ...PE 607 USA_FA 2 1 50 Wiring diagrams ...
Страница 51: ...Wiring diagrams 51 Installation Manual PELLEMATIC SmartXS ...
Страница 52: ...PE 607 USA_FA 2 1 52 Wiring diagrams ...
Страница 89: ...Parts list 89 1 17 7 Parts list 17 1 Pellematic SmartXS Installation Manual PELLEMATIC SmartXS ...
Страница 96: ...PE 607 USA_FA 2 1 96 Pellet boiler cautionary markings ...
Страница 97: ...Pellet boiler cautionary markings 97 Installation Manual PELLEMATIC SmartXS ...
Страница 98: ......
Страница 99: ......