81
13.12 Motor extraction auger 1 - RA (Fault 5026)
Display:
[5026] Motor ext auger1
Description:
Storage room auger 1 motor defect – Output RA
Cause and Remedy:
Motor unplugged
►
Plug in motor, check cable connections
motor is jammed
►
Remove pellets and dust from auger and make su-
re auger rotates freely
Motor defect
►
Replace motor
Thermic contact triggered
►
Let motor cool down
Motor not running
►
Check thermic contact
13.13 Hopper motor (Fault 5028)
Display:
[5028] Hopper motor
Description:
Hopper suction fan fault. Output RES1.
Cause and Remedy:
Motor unplugged
►
Plug in motor, check cable connections
Motor defect
►
Replace motor
13.14 Emergeny OFF/ Safety temperature (Fault 5032, 5033)
Display:
[5032] Emergeny OFF – NOT AUS
Description:
Emergency OFF has been actuated – Input NOT-AUS
Cause and Remedy:
Emergency OFF
unplugged
►
Connect up Emergency OFF and check cable
connections
Emergency OFF button
has been pressed
►
Reset Emergency OFF switch
Emergency OFF defect
►
Replace Emergency OFF switch
Display:
[5033] Safety temperature - STB
Description:
Safety temperature limiter has tripped – Input STB
Cause and Remedy:
Safety temperature limiter
unplugged
►
Connect up safety temperature limiter and check
cable connections
Safety temperature limiter
has tripped
►
Let boiler cool down and reset safety temperature
limiter
Safety temperature limiter
defect
►
Replace safety temperature limiter
A 230V Output is defect
►
Check 230V Outputs
13.15 Temperature Combustion chamber sensor/Flue gas sensor (Fault 5034, 5036)
Display:
[5034] PE Ignition fault / Pellets available?
Description:
Minimum temperature Combustion chamber sensor/Flue gas sensor not reached
durring the ignition phase
Cause and Remedy:
No pellets available
►
Fill up with pellets
Ignition electrode defect
►
Check ignition electrode (approx. 200
Ω
) replace if
required
Ignition nozzle blocked
►
Clean burner plate and ignition tube
Installation Manual PELLEMATIC® SmartXS
Содержание PELLEMATIC SmartXS
Страница 28: ...Dismantling sequence of the housing parts PE 607 USA_FA 2 1 28 Dismantling of the housing parts ...
Страница 29: ...Dismantling of the housing parts 29 Installation Manual PELLEMATIC SmartXS ...
Страница 30: ...PE 607 USA_FA 2 1 30 Dismantling of the housing parts ...
Страница 45: ...Suggested piping arrangement for combined operation 45 Installation Manual PELLEMATIC SmartXS ...
Страница 49: ...Wiring diagrams 49 Installation Manual PELLEMATIC SmartXS ...
Страница 50: ...PE 607 USA_FA 2 1 50 Wiring diagrams ...
Страница 51: ...Wiring diagrams 51 Installation Manual PELLEMATIC SmartXS ...
Страница 52: ...PE 607 USA_FA 2 1 52 Wiring diagrams ...
Страница 89: ...Parts list 89 1 17 7 Parts list 17 1 Pellematic SmartXS Installation Manual PELLEMATIC SmartXS ...
Страница 96: ...PE 607 USA_FA 2 1 96 Pellet boiler cautionary markings ...
Страница 97: ...Pellet boiler cautionary markings 97 Installation Manual PELLEMATIC SmartXS ...
Страница 98: ......
Страница 99: ......