Not enough draught
►
Check ventilation flap, funktion radial fan, draught
free
Flue gas sensor or flamm-
roomtemperature-sensor
soiled
►
Check Flue gas sensor or flammroom-temperatu-
re-sensor
Display:
[5036] PE Flame supervision fault
Description:
Flame supervision fault, minimum flue gas temperature not reached during heating
up at full power – Input FRT
Cause and Remedy:
No pellets available
►
Fill up with pellets
13.16 Flame return gate BSK (5038, 5039, 5040)
Display:
[5038] PE Flame return gate open
Description:
Flame return gate open fault (BSK - 1 2)
Cause and Remedy:
Flame return gate
unplugged
►
Connect up flame return gate and check cable
connections
Flame return gate does
not reach OPEN limit
switch
►
Check ball valve to see if it is jammed
No signal although open
►
Check cables and flame return gate
STB on the burner has
triggered
►
Surface temperature of the burner is too high
Display:
[5039] PE Flame return gate closed
Description:
Flame return gate open fault
Cause and Remedy:
Flame return gate
unplugged
►
Connect up flame return gate and check cable
connections
Flame return gate does
not reach CLOSE limit
switch
►
Check whether ball valve is jammed, check ball
valve throughway to see if foreign objects are pre-
venting it from closing
No signal although closed
►
Check cables and flame return gate
STB on the burner has
triggered
►
Surface temperature of the burner is too high. The
boiler switches to fault mode.
Display:
[5040] PE Flame return gate limit switch
Description:
Both flame return gate limit switches (BSK 1-2 and BSK 3-4) are closed at the same
time
Cause and Remedy:
Both limit switches
activated
►
Check flame return gate, check cables, check
connectors
13.17 Suction system (Fault 5043)
Display:
Suction system
Description:
Hopper cannot be filled up even after 3 suction cycles
Cause and Remedy:
Storage room empty
►
Fill up with pellets
Extraction system is
blocked
►
Clear extraction system
PE 607 USA_FA 2.1
82
Содержание PELLEMATIC SmartXS
Страница 28: ...Dismantling sequence of the housing parts PE 607 USA_FA 2 1 28 Dismantling of the housing parts ...
Страница 29: ...Dismantling of the housing parts 29 Installation Manual PELLEMATIC SmartXS ...
Страница 30: ...PE 607 USA_FA 2 1 30 Dismantling of the housing parts ...
Страница 45: ...Suggested piping arrangement for combined operation 45 Installation Manual PELLEMATIC SmartXS ...
Страница 49: ...Wiring diagrams 49 Installation Manual PELLEMATIC SmartXS ...
Страница 50: ...PE 607 USA_FA 2 1 50 Wiring diagrams ...
Страница 51: ...Wiring diagrams 51 Installation Manual PELLEMATIC SmartXS ...
Страница 52: ...PE 607 USA_FA 2 1 52 Wiring diagrams ...
Страница 89: ...Parts list 89 1 17 7 Parts list 17 1 Pellematic SmartXS Installation Manual PELLEMATIC SmartXS ...
Страница 96: ...PE 607 USA_FA 2 1 96 Pellet boiler cautionary markings ...
Страница 97: ...Pellet boiler cautionary markings 97 Installation Manual PELLEMATIC SmartXS ...
Страница 98: ......
Страница 99: ......