![OKIDATA ML1120 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/okidata/ml1120/ml1120_maintenance-manual_729916070.webp)
43471801TH Rev.1
70 /
Oki Data CONFIDENTIAL
There is no response when turning On the power switch. (No lamps illuminate.)
Is the AC cord conduction normal?
N: Replace the AC cord.
Y: Is the AC fuse (F1) in the Pow Unit burned out?
Y: Replace the fuse (F1).
N: Is the LF Motor Cable disconnected from the LF MOT Connector on the
L09 print circuit board, or is the SP Motor Cable disconnected from the
SP MOT Connector on the L09 print circuit board?
Y: Connect the Motor Cable to the L24 print circuit board properly.
N: Is the LF Motor Cable broken?
Y: Replace the LF Motor.
N: Is the SP Motor Cable broken?
Y: Replace the SP Motor.
N: Is the voltage in the table bellow being out
put to the connector (POW) for the Pow
Unit?
Y: Is the power cord connected
properly?
N: Reconnect the cord
properly.
Y: Replace the Pow Unit.
1
Connector
CN1
Pin No.
1, 2, 12~15
4, 5, 11
6, 10
7~9
Voltage
+35V
0V (logic-type)
+5V
0V (drive-type)
The carriage does not move at power ON and only lamp some illuminates faintly.
Replace the L09 print circuit board.
2
Some lamps do not illuminate (although the carriage moves.)
Is the operator panel connector (OP) cord properly?
N: Connect the cord properly.
Y: Replace the LSO print circuit board.
N: Replace the L09 print circuit board.
3