![OKIDATA ML1120 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/okidata/ml1120/ml1120_maintenance-manual_729916056.webp)
43471801TH Rev.1
56 /
Oki Data CONFIDENTIAL
No.
Specification
Drawing
Adjustment method
4.4
(1) Set paper with 55
kg ream weight.
(2) Turn on power
while holding
down
1
SW.
(3) Press
4
SW and
print the menu
pattern.
Check to confirm that
the horizontal regis-
tration error is within
the specified range.
Correcting both-
direction print
registration
Within
±
0.1
mm
Item
±
0.15
Forward
Reverse
Correct print registration in the forward direction if
the output is reversed.
Check the registration both on a cut sheet and a
continuous form.
If this lies outside
the specified range;
(1) Turn on power
while holding
down
1
SW.
(2) You will enter
menu mode.
(3) Select a group
while holding
down
1
SW.
(4) Select an item
while holding
down
2
SW.
(5) Pressing
3
SW
will move the
printing position
+0.035 mm from
the reference
position.
(Pressing
3
SW and
4
SW simultane-
ously will shift the
position -0.035 mm.)
(6) After making the
corrections and
while holding
down
4
SW,
press
3
SW and
2
SW simultane-
ously to register
the correction
value into printer
memory.
ex) ML 1120 menu print pattern is shown.
Check print registration here.
Set-Up
Print Registration 1
LOAD
TEAR+LOAD
0
LOAD
TEAR+LOAD
0
Print Registration 2
Set-Up
LOAD
TEAR+LOAD
0
Print Registration 3
Set-Up
Move 0.35 mm to the right from the reference position.
Move 0.32 mm to the right from the reference position.
Move 0.28 mm to the right from the reference position.
Move 0.25 mm to the right from the reference position.
Move 0.21 mm to the right from the reference position.
Move 0.18 mm to the right from the reference position.
Move 0.14 mm to the right from the reference position.
Move 0.11 mm to the right from the reference position.
Move 0.07 mm to the right from the reference position.
Move 0.04 mm to the right from the reference position.
Reference position
Move 0.04 mm to the left from the reference position.
Move 0.07 mm to the left from the reference position.
Move 0.11 mm to the left from the reference position.
Move 0.14 mm to the left from the reference position.
Move 0.18 mm to the left from the reference position.
Move 0.21 mm to the left from the reference position.
Move 0.25 mm to the left from the reference position.
Move 0.28 mm to the left from the reference position.
Move 0.32 mm to the left from the reference position.
Move 0.35 mm to the left from the reference position.
+10
+9
+8
+7
+6
+5
+4
+3
+2
+1
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
Correction
Preset