TROUBLESHOOTING AND REPAIR
6.1
Items to Check Before Repair
(1)
Check the inspection items specified in the instruction manual.
(2)
Find out as many details of the trouble as possible from the customer.
(3)
Inspect in the conditions as close as possible to those at the time the trouble occurred.
(4)
Proceed with the repair as follows:
Check the trouble status according to Table 6.1 for the details of the trouble. Then, locate
the trouble position according to the detailed flowchart.
(5)
Carry out a thorough test after the repair to check for correct functioning.
• Allocation of switch lamps
A
B
C
D
1
1
1
1
1
2
2
2
2
2
3
3
3
3
3
4
4
4
4
4
• Indicator Light Functions
SEL
ALARM
STATUS 1
STATUS 2
Green
Red
Green
Green
• Indicates SELECT (ready to
receive) status.
• Indicates power saving
status (lit dim).
• Indicates paper end status.
• Indicates the font, character
pitch, and print mode.
• Indicates the font, character
pitch, and print mode.
• Indicates DESELECT state
(not ready to receive).
• Indicates existence of no
alarms.
• Indicates the font, character
pitch, and print mode.
• Indicates the font, character
pitch, and print mode.
• Flashes with ALARM LED
and indicates unrecoverable
status alarm. (Both main
and sub flashes)
• Indicates print suppression
status.
• Indicates head thermal
alarm (quiescent) status.
• Flashes with SEL LED and
indicates unrecoverable
status alarm. (Main flash)
• Indicates paper jam status.
• Indicates media alarm status.
• Indicates the font, character
pitch, and print mode.
• IIndicates the font, character
pitch, and print mode.
LED
Color
Stays lit
Stays off
Flashes