43471801TH Rev.1
47 /
Oki Data CONFIDENTIAL
3.3.16 Bottom sensor, photo interrupter and sensor cord (6P)
(1)
Remove the upper cover.(See. 3.3.4)
(2)
Remove the printer unit.(See. 3.3.6)
(3)
Remove the platen.(See. 3.3.5)
(4)
Remove the paper pan Assy.(See. 3.3.15)
(5)
Release the two claws of the sensor arm holder Assy.
1
and remove the paper pan Assy.
(6)
Remove the sensor arm
2
.
(7)
Open the two claws and remove the bottom sensor
3
.
(8)
Remove the photo interrupter
4
.
(9)
Remove the sensor cable (1P)
5
from the bottom sensor
3
and photo interrupter
4
.
(10) To perform mounting, follow the reverse procedure of removal.
Remake on Assembly
(1) After assembling, make sure that the sensor arm moves smoothly.
1
2
5
3
4
peper pan Assy