Sequential Numbering
Command Structure
<ESC>Faaaabcccc,dd,ee
aaaa
=
Number
of
times
to
repeat the same data (0001 ~ 9999).
b
=
Plus or minus symbol (+ for increments, – for decrements).
cccc
=
Value
of
step
for sequence (0001 ~ 9999).
dd
=
Number of digits for sequential numbering (01 ~ 99). The first
incrementing
character
position
starts
after
the
positions
exempted
from sequential numbering as specified in ee. If these digits are left
out,
the
default
is
8.
ee
=
Number of digits free from sequential numbering (0 ~ 99) starting
with the right most position. If these digits are left out the default is
0.
Example: <ESC>F001-001,4,3
Decrementing
004321321
Free
from
Decrementing
In this example, the right most (least significant) three digits would
not
decrement
and
the
next
four
would
decrement.
Placement:
Preceding
that
start
value to be incremented or decremented.
Default:
None.
Command Function
To allow the ability to print sequential fields (text, bar codes) where all incre-
menting is done within the printer. Up to eight different sequential fields can be
specified per label. Sequencing is effective for up to 99-digit numeric data
each
field.
Input to Printer
<ESC>A
<ESC>H100<ESC>V100<ESC>MSERIAL NUMBER:
<ESC>H100<ESC>V200<ESC>F001+005
<ESC>L0202<ESC>M1000
<ESC>Q2<ESC>Z
69