Print Quantity
Command Structure
<ESC>Qaaaaaa
aaaaaa =
Total
number
of
labels to print (1 to 65535).
Placement:
Just
preceding
<ESC>Z.
This command must be present in every
print job.
Default:
<ESC>Q1
Command Function
To specify the total number of labels to print for a given print job.
Input to Printer
<ESC>A
<ESC>H100<ESC>V100<ESC>WB1OKI
<ESC>Q3<ESC>Z
Printer Output
Three labels containing the data “OKI” will be printed.
Special Notes
1.
To cancel a print job, you must turn off the printer.
2.
When used with <ESC>F Sequential Numbering command (see page 69),
the Print Quality value should be equal to the total number of labels to be
printed.
3.
If you do not specify a Print Quantity, one copy is assumed.
4.
For this commands, leading zeroes do not have to be entered. The com-
mand
Q1
is
equivalent
to
Q000001.