OKIFAX 5700/5900
1 - 22
No.
Item
Specifications
8
Power outage report
9
Confidential reception report
10
Protocol dump (G3)
11
Self-diagnosis report
12
Log report
13
Function list
14
Group directory
15
Protocol dump (G4)
16
NIC (Network Interface Card)
configuration
If received communications are lost due to power failure,
this report is printed out automatically at power recovery.
The information printed on the Power outage report is not
printed out on the Activity report.
See Fig. 1-6-8
This report will be informed operator about a stored
confidential messages in the memory and automatically
printed out.
See Fig. 1-6-9
This report will be manually printed out for maintenance
purpose.
If the previous communication is G3, G3 communication
protocol dump is printed out.
(MEMU key
∅
Report Print)
See Fig. 1-6-10-1 and Fig. 1-6-10-2
This report will be manually printed out for maintenance
purpose.
(To check ROMs, RAMs and Printing function.)
(MENU key
∅
RESOLUTION key twice
∅
Technical
PRG
∅
Local Test
∅
Self-diagnosis)
See Fig. 1-6-11-1 and Fig. 1-6-11-2
This report will be manually printed out for fault analysis.
(MENU key
∅
Report Print)
See Fig. 1-6-12
This list can be printed out manually from the report
operation.
This list is printed out user function only and does not print
technical function.
(MENU key
∅
Report Print)
See Fig. 1-6-13-1 to Fig. 1-6-13-6
This list can be printed out manually for a selected group
only (Group #1 to #20) through operation. This list cannot
output all group at a time.
If Group is omitted, report will not be printed out.
(MENU: No.8
∅
Report Print: No.4)
See Fig.1-6-14-1 to Fig. 1-6-14-4
This report will be manually printed out for maintenance
purpose.
If it is G4, the G4 communication protocol dump is printed
out.
(MENU: No.8
∅
Report Print: No.8)
See Fig. 1-6-15-1 and Fig. 1-6-15-2
This report will be manually printed out for maintenance
purpose.
(MENU: No.8
∅
Report Print: No.9)
See Fig. 1-6-16-1 and Fig. 1-6-16-2
This report is not available for localization.
Содержание OKIFAX 5700
Страница 6: ...CHAPTER 1 GENERAL INFORMATION ...
Страница 90: ...CHAPTER 2 INSTALLATION PROCEDURE ...
Страница 102: ...OKIFAX 5700 5900 2 12 3 Document stacker Hang the document stacker onto hanging position ...
Страница 204: ...OKIFAX 5700 5900 2 114 Typical Transmission flow ...
Страница 205: ...OKIFAX 5700 5900 2 115 Typical Reception flow ...
Страница 210: ...CHAPTER 3 BRIEF TECHNICAL DESCRIPTION ...
Страница 218: ...CHAPTER 4 MECHANICAL DISASSEMBLY AND REASSEMBLY ...
Страница 223: ...OKIFAX 5700 5900 4 5 Appearance of the OKIFAX 5700 5900 ...
Страница 248: ...CHAPTER 5 ADJUSTMENTS ...
Страница 252: ...CHAPTER 6 CLEANING AND MAINTENANCE ...
Страница 278: ...CHAPTER 7 TROUBLESHOOTING AND REPAIR FOR OKIFAX 5700 5900 ...
Страница 326: ...Appendix A PC Board Descriptions and Operation FirstEdition February 1999 Oki Data Corporation ...
Страница 390: ...C34 OKIFAX 5700 5900 A3 40 IC201 Pin Assignment ...
Страница 405: ...Appendix B DescriptionsofPrintOperation ThirdEdition December 1998 Oki Data Corporation ...
Страница 427: ...Appendix C Not used at this time ...
Страница 430: ...OKIFAX 5700 5900 D 1 Section 1 CABINET ASSEMBLY ...
Страница 432: ...OKIFAX 5700 5900 D 3 Section 2 CONTROL PANEL ASSEMBLY ...
Страница 434: ...OKIFAX 5700 5900 D 5 Section 3 PRINTER ASSEMBLY 53 54 ...
Страница 437: ...OKIFAX 5700 5900 D 8 Section 4 BASE ASSEMBLY ...
Страница 439: ...OKIFAX 5700 5900 D 10 Section 5 FRAME ASSEMBLY SCANNER L ...
Страница 441: ...OKIFAX 5700 5900 D 12 Section 6 FRAME ASSEMBLY SCANNER U ...
Страница 443: ...OKIFAX 5700 5900 D 14 Section 7 CABLES OPTION BOARDS ...
Страница 445: ...Appendix E Not used at this time Oki Data Corporation ...
Страница 446: ...Appendix F Not used at this time Oki Data Corporation ...
Страница 447: ...Appendix G PC Loading FirstEdition February 1999 Oki Data Corporation ...
Страница 465: ...Appendix H RMCS SYSTEM MANUAL For Model 30 FirstEdition Oki Data Corporation ...
Страница 466: ......