![Oki ML670100 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/oki/ml670100/ml670100_user-manual_4174189047.webp)
Chapter 3 Setup and Operation
Page 3-17
The user connector Board (USRCN) has four connectors, labeled CNU1 to CNU4, that plug
into their counterparts on the Oki ML670100 CPU Board and two, labeled CNA and CNB, for
connecting the user cable.
The user cable has two connectors, labeled CNA and CNB, that plug into their counterparts
on the user connector Board (USRCN) and a 144-pinTQSOCKET for connecting the user
application system.
Below are the procedures for connecting both ends of this cable.
(1) Plug user connector Board (USRCN) connectors CNU1 to CNU4 into their counterparts on
the Oki ML670100 CPU Board.
Figure 3.20.
Connecting to User Application System (1/2)
(2) Connect the TQSOCKET to the user application system.
Plug the user cable 144-pinTQSOCKET into a suitable connector provided in the user
application system.
Figure 3.21 shows one such connection.
POWER
ANGEL
RESET
+5.0V
CNJ
CNU2
EXPCN
OKI
ML670100 CPU
BOARD
MTU-11037
VREFSEL
SYSTEM
USER
OSCSEL
SYSTEM
USER
MODE
ANGEL
NORMAL
CNU4
CNU3
CNU4
RS232C
ENA
DIS
IN
EXT
VDDSEL
1
3
EIR0
1
3
EFIQ
EFIQ
EIR0
3
3
3
3
CNB
1
2
80
79
CNA
1
2
80
79
J2
J1
J4
J3