When
BLT REFLECT TEST
is executed:
a.
A color registration adjustment belt reflection test starts (the ONLINE lamp
starts blinking).
b.
When the test ends, the upper display shows the result of the test (OK or an
error name), the lower display shows ****RESULT.
Pressing
[2]
displays the next test result. Pressing
[8]
displays the preceding test
result. Pressing
[4]
restores the state for step 2.
c.
Pressing the [#] button during the test cancels the test (turning on the
ONLINE lamp), restoring the state for step 2.
When
BLT REFLECT RSLT
is executed:
Same button operations as used when BLT REFLECT TEST is executed.
Remark:
While the printer is initialized or issues an alarm or the cover is open, it
displays the following message.
4.
Repeat steps 2 and 3 when necessary.
5.
Press [4] to end the test (the state for step 1 is restored).
Color registration adjustment test items
Display Detail
Display Detail
REG ADJ EXECUTE Executes color registration adjustment.
REG ADJ RESULT
Displays the result of color registration adjustment.
BLT REFLECT TEST
Judges whether color registration adjustment belt reflection is proper or
not
BLT REFLECT RSLT
Displays the result of color registration adjustment belt reflection
judgment.
2.8.5 Density Adjustment Test
The density adjustment test is used for performing a density adjustment function test and
displaying the result of it to judge whether the density adjustment mechanism is proper.
1.
Enter the self-diagnostic-mode and, until the following message appears, press
[2]
or
[8]
.
33