U
: Three asterisks (***) identifies a measured upper heater temperature
(in Celsius). Three sharp signs in square brackets ([###]) identifies a target
print temperature (in Celsius).
L
: Three asterisks (***) identifies a measured lower heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a read
lower thermistor AD value (in hex).
T
: A measured ambient temperature (in Celsius).
H
: A measured ambient humidity (in percent figures).
The displays are switched by pressing
[2]
.
YTR
,
MTR
,
CTR
and
KTR
indicate the set transfer voltage values for
colors, respectively (in kV).
The displays are switched by pressing
[2]
.
KR
: A black transfer roller resistance value (in uA).
YR
: A yellow transfer roller resistance value (in uA).
MR
: A magenta transfer roller resistance value (in uA).
CR
: A cyan transfer roller resistance value (in uA).
The displays are switched by pressing
[2]
.
ETMP
: A parameter for correction of constant hopping motor speed (an
ambient temperature) (in decimal).
UTMP
: A parameter for correction of constant fuser motor speed (a target
fusing temperature) (in decimal).
REG
: A hopping motor constant-speed timer value (a set input/output
value) (in hex).
EXT
: A fuser motor constant-speed timer value (a set input/output value)
(in hex).
The displays are switched to the following by pressing
[2]
.
ID
: An image drum motor constant-speed timer value (a set input/output
value) (in hex).
30