18
Solenoid Test
Value:
Once
Continuous
After a short press of the button, intake for 2 seconds and then stop.
After a long press of the button, intake for 2 seconds and stop for 3 seconds repeat
Stop when the Stop button is pressed.
Deemed successful at all times. No need to display results.
Display "Testing" during execution?
→
Display a message on the panel showing that testing is underway.
2.7 Fax Maintenance
Note: This menu not shown on models with no fax.
Service Bit
Note: This is displayed only for destinations "JP1" and "JPOEM."
Country Code
This is displayed only for destinations "JP1" and "JPOEM."
Line Test
Tone Send Test
Value: 2100Hz 1850Hz 1650Hz 1100Hz
Tone send test conducted.
DP Send Test
Value: 0 ~ 9, #, * Key
DP send test conducted.
MF Send Test
Value: 0 ~ 9, #, * Key
MF send test conducted.
Modem Signal Send Test
Value:
V.34 (33.6Kbps)
V.34 (28.8Kbps)
V.17 (14.4Kbps)
V.17 (12.0Kbps)
V.17 (9.6Kbps)
V.17 (7.2Kbps)
V.29 (9.6Kbps)
V.29 (7.2Kbps)
V.27 (4.8Kbps)
V.27 (2.4Kbps)
V.21 (0.3Kbps)
Modem-signal send test conducted. 11 types available, including V. 34 (33.6 Kbps).