15
Adjust Mech.
FB Drive Current
Value: 1 ~ 140
Connect a panel or PC and set the electric current value of the scanner motor
.
FB Keep Current
Value: 1 ~ 140
ADF Drive Current
Value: 1 ~ 140
ADF Keep Current
Value: 1 ~ 140
Adjust CIS
Adjust CIS
Value:
simple/R continuous/G continuous/B continuous/All continuous
Sequentially light the designated RGB colors and check them during calibration
configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in the same
manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→
On the panel, display "CIS light testing" and "Cancel."
Check
CIS
Value: 300dpi/600dpi/1200dpi
-- Results displayed ---
CCD_SIG9_WID_H 0 x 000000
CCD_SIG2_WID_H 0 x 000000
Check CIS maintenance displays the exposure time at each resolution.
When resolution is set, scanner calibration is conducted at that resolution and the
following results are displayed:
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
Note:
CIS exposure time varies with resolution.
Set CIS Exposure Time
Value: 0 ~ 4294967295
Change LED exposure time settings, and then read the document using PC Scan.
Reading implemented for the LED exposure time in the settings, without
conducting calibration. A warning is displayed when a value greater than the
Lsync cycle has been set.
Settings are shown below.
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync