75
Self Diagnostic Error Codes
Code
Cause/Description
Remedy
231
RFID Reader is not installed. RFID read device error
Check connections of the RFID R/W PCB.
Replace the RFID R/W PCB
Replace the P6X PCB.
901 - 904
Belt temperature is abnormal.
901:
Short circuit.
902:
Open circuit.
903:
High temperature.
904:
Low temperature.
Is the cable between the belt thermistor and high voltage
PCB connected normally?
Re-connect the cable properly.
Turn OFF the power and back ON.
Replace the Belt thermistor
918
Duplex FAN Alarm. Duplex internal FAN error.
Check that the Duplex unit is installed properly.
Check that the FAN is connected properly.
Replace the FAN.
923
Black image drum lock error. K ID does not rotate
properly.
Check that the K ID is installed properly.
Replace the K ID unit.
Replace the K ID motor.
928
Fuser motor lock error. Fuser does not rotate properly.
Check that the Fuser is installed properly.
Replace the fuser unit.
Replace the fuser motor.
980
Media jamming error around the fuser. Media is jammed by
entangling around the fuser.
Replace the fuser unit.