Pulse Make Ratio
Default 40%
Sets the make ratio of DP (10 pps) during call.
MF
(Tome)
Duration
ON
Period
Range
0 - 1 ms to 255 ms
Default 80ms
Sets the ON period of MF (Tone) Duration send. When the setting value is “0”, the MFP
runs at the initial value of each country. When the set value is except "0", the set value
operates at 1 to 255m second.
OFF Period
Range
0 - 1 ms to 255 ms
Default 70ms
Sets the OFF period of MF (Tone) Duration send. When the setting value is “0”, the MFP
runs at the initial value of each country. When the set value is except "0", the set value
operates at 1 to 255m second.
Calling Timer
Range
0 - 1 second to 255 seconds
Default 55 seconds
Sets the Calling Timer. When the setting value is “0”, the MFP runs at the initial value of
each country. When any value other than “0” is set, the Calling Timer can be selected in
the range of 1 to 255 mm.
Attenuator
Range
0 dB to -15 dB
Sets the Attenuator. It can be set in units of 1 dB. When the “Country code” is set to
“Japan”, it can be set in the range of 8 to 15 dB.
MF Attenuator
Range
0 dB to -15 dB
Default 70dB
Sets the MF Attenuator. It can be set in units of 1 dB.
Line Test
When “Line Test” is selected, the following screen is displayed. Select the desired test
item to be implemented.
Relay Test
Implements the relay ON/OFF test.
Relay test procedure
Press the [Relay] button on the "Line Test” screen.
Select the desired relay that is going to receive the ON/OFF test.
When the [Close] button is pressed, the screen returns to the “Line Test” screen.
When the [Reset] key is pressed, screen returns to the top screen of the service menu.