OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-68
Error
No.
Cause
User Solution
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
Assumed Replacement
Part
Reference to
Check/Replace
Parts
1500
PCB-ASSY-TRC-MW
Connection Error
Restart the printer.
Check the connection of
CABLE(TRC-CTL)-ASSY(MW).
- CABLE(TRC-CTL)-ASSY(MW)
- PCB-ASSY-TRC-MW
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
1600
RSM Register Read/Write Error Restart the printer.
Install the last firmware version.
- PCB-ASSY-IPB5-100
1610
Flash Check Sum Error
Restart the printer.
ditto
- Firmware version
- PCB-ASSY-IPB5-100
1620
PCB-ASSY-IPB5-100
Initialization Error
Restart the printer.
Install the last firmware version.
- PCB-ASSY-IPB5-100
1630
Band Memory Read/write Error Restart the printer.
ditto
ditto
1640
USB Chip Register Read/write
Error (Peripheral)
Restart the printer.
ditto
ditto
1641
USB Chip Register Read/write
Error (Host)
Restart the printer.
ditto
ditto
1650
EEPROM Initialization Check
Error
Restart the printer.
Check the connection of
IC(EEPROM).
- IC(EEPROM)
- PCB-ASSY-IPB5-100
1660
RSM Mask Memory Read/write
Error
Restart the printer.
Install the last firmware version.
PCB-ASSY-IPB5-100
1670
ATG Register Read/write Error
Restart the printer.
ditto
ditto
1700
ABC Register Read/write Error
Restart the printer.
ditto
ditto
1800
PTG Register R/W Error
Restart the printer.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
- ROBOT CABLE,MW
1900
Power Supply Unit Error
(PCB-ASSY-ACT3 P12V)
Restart the printer.
- Check the connection of
CABLE(ACT-IPB-IF)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT-IF)-ASSY(MW).
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Power supply unit (38V)
1901
Power Supply Unit Error
(PCB-ASSY-ACT3 P24V)
Restart the printer.
ditto
ditto
1902
Power Supply Unit Error
(PCB-ASSY-ACT3 P24VAR)
Restart the printer.
Check the connection of the
interlock switch connectors.
- Window sensor OKI Data
Infotech
- PCB-ASSY-ACT3
- Power supply unit (24V)
- PCB-ASSY-IPB5-100
1903
Power Supply Unit Error
(PCB-ASSY-ACT3 P24VSF)
Restart the printer.
- Check the connection of
CABLE(ACT-IPB-IF)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT-IF)-ASSY(MW).
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Power supply unit (38V)
1905
Power Supply Unit Error
(PCB-ASSY-ACT3 P38V)
Restart the printer.
ditto
ditto
1906
Power Supply Unit Error
(PCB-ASSY-ACT3 P38VAR)
Restart the printer.
Check the connection of the
interlock switch connectors.
- Window sensor OKI Data
Infotech
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Power supply unit (38V)
1907
Power Supply Unit Error
(PCB-ASSY-ACT3 P38VAF)
Restart the printer.
- Check the connection of
CABLE(ACT-IPB-IF)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT)-ASSY(MW).
- Check the connection of
CABLE(PSU-ACT-IF)-ASSY(MW).
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Power supply unit (38V)
1908
Power Supply Unit Error
(PCB-ASSY-IPB5-100
P38VAF)
Restart the printer.
ditto
ditto
1909
Power Supply Unit Error
(PCB-ASSY-IPB5-100
P38VCRG)
Restart the printer.
- Check the connection of the
interlock switch connectors.
- Window sensor OKI Data
Infotech
- PCB-ASSY-ACT3
- PCB-ASSY-IPB5-100
- Power supply unit (38V)
190a
Power Supply Unit Error
(ACT P36VARHCB)
Restart the printer.
ditto
ditto
1a00
Carriage Power Error (CRG
P38VAF)
Restart the printer.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
1a01
Carriage Power Error (CRG
PREF)
Restart the printer.
ditto
ditto
1a02
Carriage Power Error (CRG
P1.2V)
Restart the printer.
ditto
ditto
1a03
Carriage Power Error (CRG
P3.3V)
Restart the printer.
ditto
ditto
Содержание IP-6620
Страница 153: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 3 Maintenance Mode Functions and Operations 3 113...
Страница 562: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 8 Operation Mechanism 8 41 8 11 2 Block diagram...
Страница 564: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 2 Appendix 1 Power Interlock Wiring Diagram...
Страница 565: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 3 Appendix 2 Carriage IPB5 Interface Wiring Diagram...
Страница 566: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 4 Appendix 3 Carriage ADJ1 Interface Wiring Diagram...
Страница 567: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 5 Appendix 4 Blower Fan Wiring Diagram...
Страница 568: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 6 Appendix 5 Actuator Wiring Diagram...
Страница 569: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 7 Appendix 6 Take Up Unit Feed Unit Wiring Diagram...
Страница 570: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 8 Appendix 7 Ink Cartridge Wiring Diagram CIS model...
Страница 571: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 9 Appendix 8 Ink Cartridge Wiring Diagram LCIS model...
Страница 572: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 10 Appendix 9 Subtank Unit Wiring Diagram...