Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-95
5.5.20 System Error 190x: Power Supply Unit Error
<Description>
Voltage errors are detected when the following power voltages are checked.
X
Board
Power name
Power supply
system
Reference
0
PCB-ASSY-ACT3
P12V
PSU38V
ACT3
-
1
PCB-ASSY-ACT3
P24V
PSU24V
ACT3
-
2
PCB-ASSY-ACT3
P24VAR
PSU24V
ACT3
The power is cut by the interlock
3
PCB-ASSY-ACT3
P24VSF
PSU38V
ACT3
-
5
PCB-ASSY-ACT3
P38V
PSU38V
ACT3
-
6
PCB-ASSY-ACT3
P38VAR
PSU38V
ACT3
The power is cut by the interlock
7
PCB-ASSY-ACT3
P38VAF
PSU38V
ACT3
-
8
PCB-ASSY-IPB5-100 P38VAF
PSU38V
ACT3
IPB5
-
9
PCB-ASSY-IPB5-100 P38VCRG
PSU38V
ACT3
IPB5
The power is cut by the interlock
A
PCB-ASSY-ACT3
P38ARHCB
PSU38V
ACT3
HCB1M
The power is cut by the interlock
*
For the details of the power supplies’ relationship, see the
Appendix 3 Power Supply Schematic Diagram
.
<Faulty part>
(1) PCB-ASSY-ACT3
(2) PCB-ASSY-IPB5-100
(3) Power supply unit (24V) (PSU 24V): POWER SUPPLY 24V, MW
(4) Window sensor OKI Data Infotech (interlock switch)
(5) Power supply unit (38V) (PSU 38V): POWER SUPPLY 36V, MW
Note:
If the PSU 38V output is cut, the power of the CPU and the peripheral circuits is also cut on the
PCB-ASSY-IPB5-100, preventing this error from occurring. Therefore the error 190X is rarely caused by
a PSU 38V problem.
Содержание IP-6620
Страница 153: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 3 Maintenance Mode Functions and Operations 3 113...
Страница 562: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 8 Operation Mechanism 8 41 8 11 2 Block diagram...
Страница 564: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 2 Appendix 1 Power Interlock Wiring Diagram...
Страница 565: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 3 Appendix 2 Carriage IPB5 Interface Wiring Diagram...
Страница 566: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 4 Appendix 3 Carriage ADJ1 Interface Wiring Diagram...
Страница 567: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 5 Appendix 4 Blower Fan Wiring Diagram...
Страница 568: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 6 Appendix 5 Actuator Wiring Diagram...
Страница 569: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 7 Appendix 6 Take Up Unit Feed Unit Wiring Diagram...
Страница 570: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 8 Appendix 7 Ink Cartridge Wiring Diagram CIS model...
Страница 571: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 9 Appendix 8 Ink Cartridge Wiring Diagram LCIS model...
Страница 572: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 10 Appendix 9 Subtank Unit Wiring Diagram...