OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-44
<Action>
Check the
Items to be Checked
on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
Action
1
Firmware
Upgrade the firmware to the latest version.
2
Connection of the harness
connector on the ambient
temperature thermistor
Check that the harness connector is securely connected to the
board
’s connector.
3
Condition of the harness on
the ambient temperature
thermistor
Check that the harness condition is proper as follows.
- The cable is not disconnected.
- The harness is not pinched by other parts.
- The cable jacket is not damaged.
If a problem is found, replace the harness.
4
Ambient temperature
thermistor
Replace the part.
Note
The ambient temperature thermistor is fixed on the SUBTANK
BOX ASSY.
5
PCB-ASSY-ACT3
Replace the PCB-ASSY-ACT3.
6
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.
When the ambient temperature is low
When the ambient temperature is high
<Description>
The ambient temperature where the printer is installed is 5°C or lower, or 35°C or higher.
<Action>
If the problem persists when the ambient temperature is between 5°C and 35°C, check the
Items
to be Checked
on the table below, and perform the actions starting from the top until the problem
is solved.
No
Items to be Checked
Action
1
Firmware
Upgrade the firmware to the latest version.
2
Connection of the ambient
temperature thermistor
harness
Check that the harness connectors are correctly connected to the
board connectors.
3
Condition of the ambient
temperature thermistor
harness
Check that the harness is not broken, trapped by other parts, or
damaged. Replace it if a problem is found.
4
Ambient temperature
thermistor
Replace the part.
Caution: The ambient temperature thermistor is secured to the
subtank unit.
5
PCB-ASSY-ACT3
Replace the PCB-ASSY-ACT3.
6
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.
DECREASE ROOM TEMP
PLEASE WARM THE ROOM
Содержание IP-6620
Страница 153: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 3 Maintenance Mode Functions and Operations 3 113...
Страница 562: ...OKI Data Infotech Corporation CONFIDENTIAL Chapter 8 Operation Mechanism 8 41 8 11 2 Block diagram...
Страница 564: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 2 Appendix 1 Power Interlock Wiring Diagram...
Страница 565: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 3 Appendix 2 Carriage IPB5 Interface Wiring Diagram...
Страница 566: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 4 Appendix 3 Carriage ADJ1 Interface Wiring Diagram...
Страница 567: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 5 Appendix 4 Blower Fan Wiring Diagram...
Страница 568: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 6 Appendix 5 Actuator Wiring Diagram...
Страница 569: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 7 Appendix 6 Take Up Unit Feed Unit Wiring Diagram...
Страница 570: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 8 Appendix 7 Ink Cartridge Wiring Diagram CIS model...
Страница 571: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 9 Appendix 8 Ink Cartridge Wiring Diagram LCIS model...
Страница 572: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 10 Appendix 9 Subtank Unit Wiring Diagram...