Self Diagnostic Error Codes (Finisher)
Code
Cause/Description
Remedy
090
Finisher Stapler Error
See Finisher Service Manual
091
Finisher Tray Elevator Error
See Finisher Service Manual
092
Finisher Bin 2 Exit Belt Motor Error
See Finisher Service Manual
093
Finisher Jogging Motor Error
See Finisher Service Manual
094
Finisher Main Feed Motor Error
See Finisher Service Manual
096-01
Paper Eject Motor Error
Check All Connections
Check / Replace Motor
Replace Finisher Control PCB
096-02
Tray Raise / Lower Error
* Replace Shift Motor & Finisher Controller as a set.
Check / Clean / Replace Upper Limit Sensor
Check / Replace Shift Motor
Check / Replace Finisher Control PCB
096-03
Aligning Motor Error
Check / Clean / Replace Alignment Sensor
Check / Replace Alignment Motor
Check / Replace Finisher Control PCB
096-04
Staple Motor Error
Check Stapler Movement / Connections
Check Stapler Home Position Sensor
Replace Motor / Sensor
096-05
Batch Processing Motor Error
Check Delivery Belt
Check Paper ejection Belt
Check Belt Home Position Sensor
096-06
Stapler Unit Feed Motor Error
Check Slide Motor
Check Home position Sensor
096-07
Paddle Motor Error
Check Paddle Movement
Check Paddle Home Position Sensor
Check Swing Guide Movement
Check Swing Guide Home Position Sensor
096-08
Folding Sensor Error
See Finisher Service Manual
096-09
Backup RAM Data Error
Check All Connections
Check / Replace Interface Cable
Replace Finisher Control PCB
Replace Engine PCB
096-10
Punch Horizontal Sensor Error
Check / Replace Sensor
096-11
Punch Debris Sensor Error
Check / Replace Sensor
096-0A
Punch Motor Error
Check / Replace Punch Motor Home position Sensor
Check / Replace Punch Motor
096-0B
Punch Feed Motor Error
Check / Replace Punch Feed Motor
Home Position Sensor
096-0C
Punch Interface Error
Check Connections
096-0D
Punch Power Failure Error
24V missing from Finisher Controller
Replace Finisher Controller
Replace Punch Controller
097
Inverter Power Supply Error. 24V not detected
Check/Re-install all finisher connectors
Replace inverter Power supply
Replace Finisher Controller
186
Interface Error
Check All Connections
Check / Replace Interface Cable
Replace Finisher Control PCB
Replace Engine PCB