CW-1RC SERIES CHECKWEIGHER
15
5.2 Starting and Stopping the CW1-RC
5.2.1 Set-Up and Run Ready Condition
In order to start filling, the following conditions must be met.
1.
The operator must ensure that there are no boxes on either conveyor. (Note:
The only time boxes should remain on either conveyor is following an emergency
stop.)
2.
The emergency stop pushbuttons pulled out, press the
RESET
pushbutton.
3.
The checkweigher must receive permission-to-operate confirmation from the
plants master controller (if interface is applied).
5.2.2 Cycle Starting / weighting
Press the
START
pushbutton.
The checkweigher will begin to accept cases from upstream equipment.
It will checkweigh boxes as long as no error conditions occur and the machine has
permission to run from the plant’s master control system (if interface is applied).
5.2.3 Cycle Stopping
Press the
STOP
pushbutton at any time
The boxes in the checkweigh station will be weighed and accepted or rejected
depending on their weight. No new boxes will enter the machine will stop.
5.2.4. Emergency Stopping
Push in either
EMERGENCY STOP
pushbutton if an emergency condition arises.
When an emergency stop is initiated all machine functions cease. That is, weighing
and rejecting stops and all PLC outputs de-energize.
To recover from an emergency stop, make sure
EMERGENCY STOP
pushbuttons
are pulled. Press blue
RESET
pushbutton to re-energize system. Proceed with
normal machine operation.
Содержание CW1-RC Series
Страница 33: ...CW 1RC SERIES CHECKWEIGHER 33 9 COMPONENT DRAWINGS 9 1 CW1 RC...
Страница 34: ...CW 1RC SERIES CHECKWEIGHER 34 9 2 Weigh Scale Conveyor Static Powered Roller System...
Страница 35: ...CW 1RC SERIES CHECKWEIGHER 35 9 3 Weighing Platform Drop down Scale Conveyor System...
Страница 36: ...CW 1RC SERIES CHECKWEIGHER 36 9 4 Electrical Panel Siemens...
Страница 37: ...CW 1RC SERIES CHECKWEIGHER 37 9 5 Electrical Operator Controls Pro face...
Страница 38: ...CW 1RC SERIES CHECKWEIGHER 38 9 6 Main Air Preparation Stack Pneumatics Norgren...