The thermostat is an electronic on/off thermo-
stat for temperature control by means of an 
NTC sensor located either externally or inter-
nally within the thermostat.
The thermostat is for flush mounting in a wall 
socket. A baseplate for external wall mounting 
is available.

PRODUCT PROGRAMME

OCC4-1991   Clock-thermostat incl. floor sensor.
OCC4-1999   Clock-thermostat with built-in 

room sensor.

OCD4-1999   Clock-thermostat with 2 sensors. 

Floor sensor and built-in room 
sensor.

WARNING

 – Important Safety Instructions. 

Disconnect the power supply before carrying 
out any installation or maintenance work on this 
control unit and associated components. This 
control unit and associated components should 
only be installed by a competent person (i.e. a 
qualified electrician). Electrical installation must 
be in accordance with appropriate statutory 
regulations.

MOUNTING OF SENSOR

The floor sensor contains a safety extra-low 
voltage (SELV) circuit, allowing it to be placed 
as close to the floor surface as necessary with-
out having to take account of the risk of shock 
should the sensor cable become damaged. The 
two wires from the sensor to the mounting box, 
must be additionally insulated, e.g. shrink flex. 
To prevent loose cables from the fixed instal-
lation from coming into contact with the 
terminal block for the floor sensor, they must be 
restrained using cable ties. 

It is recommended that the cable and sensor be 
placed in a non-conductive installation pipe em-
bedded in the floor (fig. 3). The end of the pipe 
must be sealed and the pipe placed as high as 
possible in the concrete layer. Alternatively, the 
sensor can be embedded directly in the floor. 
The sensor cable must be led through a sepa-
rate pipe or segregated from power cables.
The floor sensor must be centred between the 
heating cable. 

The sensor cable may be extended up to 100 
m by means of a separate two-core cable. Two 
vacant wires in a multi-core cable used, for 
example, to supply current to the floor heating 
cable must not be used. The switching peaks of 

such current supply lines may create interfer-
ence signals that prevent optimum controller 
function. If a shielded cable is used, the shield 
must not be connected to earth (PE). The two-
core cable must be placed in a separate pipe or 
segregated from power cables.

MOUNTING OF THERMOSTAT 

WITH BUILT-IN SENSOR

The room sensor is used for comfort tempera-
ture regulation in rooms. The thermostat should 
be mounted on the wall approx. 1.6 m above 
the floor in such a way as to allow free air circu-
lation around it. Draughts and direct sunlight or 
other heat sources must be avoided (fig. 4). No 
external sensor is connected.

Mounting of thermostat 

1.  Slide the power button down to Off “0”.
2.  Release the front cover ONLY by inserting a 

small screwdriver into the hole on either side 
of the thermostat.

3.  Connect the wires in accordance with the 

diagram (fig. 2). 

4.  Mount the thermostat in the wall socket. 
5.  Fit the frame and carefully press the cover 

onto the thermostat. Ensure that both the 
power slide button on the cover and the 
power switch pin are down.

DO NOT

 open the thermostat by releasing the 

four fixing clips on the back.

First time settings:

The first time the thermostat is connected, push 
the power slide button to On “I”. Language, time 
and date must be set using the buttons:
1.  Set language
2.  Set time 
3.  Set date

PROGRAMMING

See user manual.

FAULT LOCATION

If the sensor is disconnected or short-circuited, 
the heating system is switched off. The sensor 
can be checked against the resistance table 
(fig. 5). 

ERROR CODES

E0:   Internal error. The thermostat must be 

replaced.

E1:  Built-in sensor short-circuited or  

disconnected.

E2:  External sensor short-circuited or  

disconnected.

E5:  Overheating, The temperature is too high in  
 

the thermostat and switch off the heating. 

CE MARKING

According to the following standard: 
LVD/EMC: EN 60730-2-9

CLASSIFICATION

The product is a Class II device (enhanced 
insulation) and must be connected to in the 
following way: 
Term. 1: Neutral (N
Term. 2: Phase (L) 230 V ±10%, 50/60 Hz 
Term. 3–4: Load, max. 16 A / 3600 W
Term. X: Do not connect
Term. 5-6: External floor sensor

ENVIRONMENT AND RECYCLING

Please help us to protect the environment by 
disposing of the packaging in accordance with 
national regulations for waste processing.

RECYCLING OF OBSOLETE 

APPLIANCES

Appliances with this label must not 
be disposed of with general 
household waste. They must be 
collected separately and disposed of 
in compliance with local regulations.

 

TECHNICAL DATA

Voltage  ........................... 230 VAC ±10% 50 Hz
Max. pre-fuse .............................................. 16 A
Built-in circuit breaker ....................  2-pole, 16 A
Output relay ............ Make contact - SPST - NO
Output ................................  Max. 16 A / 3600 W
Control principle .................................... PWM/PI
Stand-by power .......................................  0.6 W 
Battery backup.......................................  5 years
Temperature range .............................. +5/+40°C
Limit sensor (OCD4) ............................ +5/+40°C
Ambient operating temperature .......... +0/+25°C
Energy monitor, accuracy ............................. 2%
Control pollution degree .................................. 2
Rated impulse voltage ................................ 4 kV
Enclosure rating ......................................... IP 21
Dimensions ..................... H/84, W/84, D/40 mm
Build-in depth ......................................... 20 mm
Display ....... 100x64 pixel STN - white backlight
EU Registered Design  ........  001101349-0001/2

The thermostat is maintenance free.

OJ ELECTRONICS A/S

Stenager 13B · DK-6400 Sønderborg
Tel: +45 73 12 13 14 · Fax: +45 73 12 13 13
[email protected] · www.oj.dk

Deutsch

Der Thermostat ist ein elektronischer On/Off-
Thermostat zur Temperaturregelung mittels 
extern angebrachten oder im Thermostat einge-
bauten NTC-Fühler.
Der Thermostat ist für Unterputzmontage in 
einer Wanddose vorgesehen. Eine Bodenplatte 
für externe Wandmontage ist lieferbar.

PRODUKTPROGRAMM

OCC4-1991   Uhr-Thermostat einschl. Bodenfüh-

ler.

OCC4-1999   Uhr-Thermostat mit eingebautem 

Raumfühler.

OCD4-1999   Uhr-Thermostat mit 2 Fühlern. 

Bodenfühler und eingebauter 
Raumfühler.

ACHTUNG

 – Wichtige Sicherheitsanweisun-

gen. Vor der Ausführung von Installations- oder 
Instandhaltungsarbeiten an dieser Regelein-
heit und zugehörigen Komponenten ist die 
Spannungsversorgung zu unterbrechen. Diese 
Regeleinheit und zugehörige Komponenten 
dürfen nur von einer fachlich befähigten Person 
(d. h. autorisierter Elektriker) installiert werden. 
Die Elektroinstallation muss in Übereinstimmung 
mit den neuesten EU-Richtlinien für elektrische 
Betriebsmittel und den diesbezüglichen Rechts-
vorschriften erfolgen.

MONTAGE DES FÜHLERS

Der Bodenfühler ist mit einem Kleinspannungs-
Sicherheitskreis (SELV) ausgestattet, womit eine 
Anbringung möglichst nahe an der Fußbod-
enoberfläche ohne Risiko von Stromschlägen 
durch ein eventuell schadhaft werdendes Füh-

•  English
•  Deutsch
•  Svenska
•  Français
•  Español
•  Nederlands
•  Polski
•  Česky

• 

Русский

• 

Українська

Содержание OCC4

Страница 1: ...tat by releasing the four xing clips on the back First time settings The rst time the thermostat is connected push the power slide button to On I Language time and date must be set using the buttons 1...

Страница 2: ...g Max 16 A 3600 W Regelprinzip PBM PI Bereitschaftsbetrieb 0 6 W Batterie Backup 5 Jahre Temperaturbereich 5 40 C Begrenzungsf hler OCD4 5 40 C Umgebungsbetriebstemperatur 0 25 C Energie auslesung gen...

Страница 3: ...lis par exemple pour alimenter le c ble chauffant ne doivent pas tre utilis s Les pics de commutation dans de tels c bles d alimentation de courant peuvent cr er des signaux interf rents qui emp chero...

Страница 4: ...Ver el manual para el usuario UBICACI N DEL FALLO Si el sensor est desconectado o en corto circuito el sistema de calefacci n se apaga Se puede veri car el sensor seg n la tabla de resistencias g 5 C...

Страница 5: ...kolwiek czynno ci monta owych lub konserwacyjnych jednost ki kontrolnej oraz pozosta ych komponent w nale y od czy zasilanie w energi elektryczn Monta i pod czenie jednostki kontrolnej oraz pozosta yc...

Страница 6: ...t na d lku a 100 m prost ednictv m samostatn ho dvou ilov ho kabelu Dva voln dr ty ve v ce ilov m kabelu pou it m nap klad pro dod vku proudu do kabelu podlahov ho vyt p n se nesm pou vat pi kov hodno...

Страница 7: ...N 2 L 230 10 50 60 N 3 4 16 A 3600 X 5 6 230 10 50 16 2 16 A SPST 16 A 3600 0 6 5 5 40 C OCD4 5 40 C 0 25 C 2 2 4 IP 21 84 84 40 20 100x64 STN 001101349 0001 2 OJ ELECTRONICS A S Stenager 13B DK 6400...

Страница 8: ...00 14800 9700 Fig 5 1 6 4 1 0 2 3 2 4 5 1 2 3 5 E0 E1 E2 E5 LVD EMC EN 60730 2 9 Fig 4 Fig 1 1 N 2 L 230 10 50 60 3 4 16A 3600 X 5 6 230 10 50 16 A 2 16 SPST NO 16 A 3600 PWM PI 0 6 5 5 40 C OCD4 5 40...

Отзывы: