© 2013 OJ Electronics A/S
3
Comfort mode
Select Comfort to set a temporary comfort temperature
(so-called party mode) for a single room or all rooms.
• Press
Comfort
, confirm with
OK
and select the room. The com-
fort temperature becomes the highest temperature for the 4-event
plan for the day concerned. Then enter the required duration of
comfort mode: 1-8 hours.
When the period has elapsed, the Central Controller will automati-
cally revert to
Auto mode
.
Frost mode
OK
Frost
Select Frost to maintain a minimum tempera-
ture for frost protection. The comfort system
maintains a minimum temperature of 10°C
(factory setting).
• Press
Frost
, confirm with
OK
and the frost
symbol will be displayed.
Manual mode
OK
Manual
Select Manual to override the pro-
grammed 4-event schedule in a zone by
setting a required temperature manually.
• Press
Manual
, confirm with
OK
and
choose the required temperature.
Auto mode
Select Auto if you want the temperature to be controlled auto-
matically via the 4-event schedule for all rooms. The clock will be
displayed.
Please note:
Auto mode can only be selected when the controller is
in one of the other modes.
Controller setup menus
The menu allows you to select the following options:
4-event settings
Allows temperature to be controlled automatically in accordance to
a program of your choice. For each of the 5 zones, you can select
temperature settings for 4 different events during the day:
Morning
Daytime
Evening
Night
OK
4-event settings
Each zone is pre-programmed with a 4-event
schedule for easy and economic heating
control, see
Preset schedule
under
Fac-
tory settings
. The schedule can be easily
changed in the following way:
1. Press
Select
and then
Menu
to activate the 4-event settings
display. Confirm with
OK
.
2. Select the zone for which you wish to make changes. Press
OK
. If
you want to change the schedule for the zone concerned, select
Schedule
in the menu and confirm with OK. The factory default is
5:2
, see following section:
Schedule
.
3. Use the Up or Down button to choose the days for which you
want to change the settings:
Mon-Fri
or
Sat-Sun
for 5:2;
Mon-
Sat
or
Sun
for 6:1; or
Mon-Sun
for 7:0. Press
OK
.
4. Now select the time and temperature for the chosen event in the
Comfort System4
TM
English
program. Press
OK
and set the start time for the event concerned.
Confirm with
OK
. Set the temperatures for this event, first room
temperature then floor temperature, and confirm with
OK.
5. After setting the required events, select
Back
in the menu to make
changes in other zones or
Exit
to return to the initial display.
Temp
OK
40.0°C
5.0°C
25°C
Time
OK
08:00
Max
06:00
Min
07:00
Schedule
For every zone, the 4-event settings follow a specific schedule.
Here, you can choose the type of weekly 4-event schedule required.
5:2
: Monday to Friday with 4 events and Saturday to Sunday with 2
events. This is the factory default.
Typically used if you work from Monday to Friday.
6:1
: Monday to Saturday with 4 events and Sunday with 2 events.
Typically used if you work from Monday to Saturday.
7:0
: Monday to Sunday with 4 individual events. Allows you to
choose individual programs for each of the seven days of
week.
Select the required 4-event schedule and confirm with
OK
.
OK
User settings
User settings
In the user settings menu you can change the
following items:
• Time and date
• Child lock
• Display settings
• Energy monitor
OK
Time and date
Time and date
Press
OK
and set the actual time in hours and
minutes.
The date will then be displayed. Set the date
and confirm with
OK
.
Child lock
OK
Child lock
Allows you to lock the comfort system set-
tings, including all thermostats, e.g. in public
or other places where you do not want the
settings changed. There are four alternative
child lock settings:
Central :
Locks only the controller.
Normal :
Locks all units, including the controller. Individual thermo-
stats can be unlocked locally.
Full :
Locks all units, including the controller. Individual thermo-
stats can only be unlocked from the controller.
Off :
Disables the child lock settings.
Confirm your choice with
OK
. The lock symbol will be shown on the
display.
The child lock can only be unlocked on the comfort system control-
ler by simultaneously pressing both the
left
and
right
buttons for 8
seconds.
OK
Display settings
Display settings
Allows you to select what is shown on the
initial display.
Temp -
-Set temp:
Shows the current temperature
setting
Содержание comfort system4
Страница 10: ...10 2013 OJ Electronics A S 4 4 16 Ethernet 16 5 I OK OK OK OK OK 120 5 OK 4 4 12 CS4 I 0 0...
Страница 14: ...14 2013 OJ Electronics A S 4 OK OK OK OK OK OK OK OK OK OK OK OK OK OK 2 30 365 OK OK OK OK OK OK 4 10 OCS4 S...
Страница 16: ...16 2013 OJ Electronics A S 4 F A AF C 30 LHt On 8 8 10 CS4TM I 0 0 2 4 4 4...
Страница 18: ...18 2013 OJ Electronics A S 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 4...
Страница 19: ...2013 OJ Electronics A S 19 Comfort System4TM English...