8
20039847GB
4.4. Connecting the Burner to the Mains
KP-6, KP-6 L, KP-6-2
Electrical connection on burner is with a plug connector. Connect the cable of the plug supplied
with the burner to the boiler thermostat. The socket has been firmly attached to the burner
housing. Disconnect the burner from the mains (burner switch in position 0) by pressing the
locking button and pulling out the plug from the socket at the same time.
1 Socket (fixed on the burner
housing)
2 Locking button
3 Plug (pull-out part)
4.5. Connecting the Burner to Oil Supply Line
On standard version the burners is equipped for two-pipe system. Two-pipe system has both
suction and return lines for fuel oil.
Note!
The by-pass plug in the oil pump must be fixed.
1
Filter
2
Suction line
3
Oil pump
4
Pressure line (to nozzle)
5
Return line
6
By-pass plug
7
Shut-off valve
8
Shut-off valve/Non-return valve
A-A
Delivery limit
Содержание KP-6