3.3.7.
Setting holiday heating circuit
At menu level Holiday heating circuit 1 (2) user can set dates when room temperature is
reduced, for example during vacation. Setting is operational only when heating circuit is set on
automatic mode.
3.3.8.
Adjusting domestic hot water temperature and mode
Domestic hot water heating can be turned off and on using tap -button at the upper left corner
of the display.
Set domestic hot water comfort setting and reduced setting temperatures at Domestic hot water
menu, operating lines 1610: Nominal setpoint and 1612: Reduced setpoint.
When domestic hot water heating is switched on, it follows time program 4. Set dates and time
periods for domestic hot water nominal setting at this menu, at other times setting is Reduced
setpoint.
3.3.9.
Domestic hot water forced charge
If domestic hot water consumption increases momentarily, perform forced charging for about 10
minutes before increase. Press tap -button from operating display for 3 seconds to activate
forced charging.
Heat pump starts to heat up water to nominal setting, even if temperature difference is not yet
reached. Function is operational, though heat pump setting is reduced or domestic hot water
mode is off.
3.3.10.
Optional time program
System has optional time program 5, which is not connected to any function.
Cooling circuit release or hot water circulation pump control can be added to time program 5
during commissioning.
Any external clock operation can be added to time program during commissioning by defining
output for it from controller. Set time period as for other time programs.