Heating circuit
2
Line
Parameter
Function
Setting
1000
Operating mode
Set operation mode.
Automatic
1010
Comfort
setpoint
Set room temperature for heating circuit to reach at comfort
setpoint.
20
1012
Reduced
setpoint
Set room temperature for heating circuit to reach at reduced
setpoint.
18
1020
Heating curve
slope
See curves at Changing heating curve.
0,8
1030
Summer/winter
heating limit
Temperature when heating circulation is stopped or started.
Operational only in automatic mode.
18
Domestic hot water
Line
Parameter
Function
Arvo
1610 Nominal
setpoint
Domestic hot water nominal setpoint temperature.
60
1612
Reduced
setpoint
Domestic hot water reduced setpoint temperature.
55
Maintenance/service
Line
Parameter
Function
Setting
7120
Economy mode
Activate economy mode.
No
Diagnostics heat source
Line
Parameter
Function
Setting
8410
Return temp
HP
Heat pump return water temperature.
8411
Setpoint HP
Heat pump return water setpoint.
8412
Flow temp HP
Condenser supply water temperature.
8427
Source inlet
temp
Heat pump inlet circuit temperature.
8429
Source outlet
temp
Heat pump supply circuit temperature.