Filtration 

Keep the fluid clean at all times to ensure long life from your hydraulic system.  Refer to the referenced Oilgear Filtration 
Recommendations bulletin 90007.  Oilgear recommends use of a filter in the pressure or return line.  Replace filter 
element(s) when the filter condition indicator reaches change area at normal fluid temperature.  Drain and thoroughly 
clean filter case.  Use replacement element(s) of same beta 10 ratio (normally a ratio of 4 with hydraulic oils). 

Fluid Cooling 

When the pump is operated continuously at the rated pressure or frequently at peak load, auxiliary cooling of the fluid 
may be necessary. Fluid temperature should not exceed limits specified in the referenced Oilgear Fluid 
Recommendations Bulletin 90000. 

Air Breather 

On most installations, an air breather is mounted on top of fluid reservoir.  It is important for the breather to be the 

adequate size to allow air flow in and out of reservoir as fluid level changes.  Keep the breather case filled to the “fluid 
level” mark.  About once every six months, remove cover, wash screen in solv

ent and allow screen to dry, clean and refill 

case to level mark and install screen.  Refer to the manufacturer's recommendations. 

Fluid: Filling and Starting Recommendations 

Refer to instruction plate on the unit, reservoir, machine and/or reference, Fluid Recommendations bulletin.  Fire 
resistant fluids and phosphate ester fluids can be used in accordance with fluid manufacturer's recommendations. 

1.

 

Pump all fluid into reservoir through a clean (beta 10 ratio of 4 or more) filter.  Fill reservoir to, but not above, 

“high level” mark on the sight gauge.

 

2.

 

Remove case drain line and fill the pump case with hydraulic fluid.

 

3.

 

Turn drive shaft a few times by hand with a spanner wrench to make sure parts rotate.  Torque to turn drive shaft 
should be 9 to 24 ft*lbs.  (12 to 32 N*m) 

With pump under minimum load: 

4.

 

Turn drive unit ON and OFF several times before allowing pump to reach full speed.  The system can usually be 
filled by running the pump and operating the control. 

The fluid level in the reservoir should decrease. Stop the pump.  DO NOT allow the fluid level to 

go beyond the “low 

level.”  If the level reaches “low level” mark, add fluid and repeat step.

 

 

With differential (cylinder) systems, the fluid must not be above “high level” when the ram is 

retracted 

or below “low level” when extended.  Bleed air from the

 system by loosening connections or opening 

petcocks at the highest point in the system.  Close connections or petcocks tightly when solid stream of 
fluid appears. 

 

 

 

Содержание XD5-100-A1

Страница 1: ...operation maintenance and troubleshooting of Oilgear s XD5 100 variable piston pump 2 Reference Material 2 1 General Reference Description Bulletin Number Oilgear Fluid Recommendation 90000 Oilgear F...

Страница 2: ...oad Sense P 1NN F or P 1NN B 10 6 1 3 Remote Pressure Compensator P RNN 12 6 1 4 Remote Pressure Compensator and Load Sense P 1NN F 14 6 1 5 Reconfiguring the Pressure Comp Load Sense Control 15 6 2 M...

Страница 3: ...phasize information provided or provide additional information which may be of benefit 4 2 Warnings This service information is designed for the maintenance of your Oilgear product It contains the inf...

Страница 4: ...equipment unless they are fully supported or blocked Failure to follow this procedure can result in serious injury or death Use correct hoses fittings and adapters with the correct SAE rating when rep...

Страница 5: ...damage to the pump and system or serious personal injury and may void the Oilgear Warranty If you have questions concerning hydraulic pressures or testing procedures please contact Oilgear before atte...

Страница 6: ...VALUE Theoretical Max Displacement In 3 rev cc rev 6 00 98 4 Rated Continuous Pressure psi bar 5 000 350 Peak Pressure psi bar 5 800 400 Maximum Speed with a flooded inlet RPM 2 600 Outlet Flowrate 1...

Страница 7: ...A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 7 of 31 Issue Date 1 4 2021 910003 5 4 Performance Chart and Inlet Condition Figure 2 XD5 100 Performance Char...

Страница 8: ...n discusses options and adjustments related to the Control Block 6 1 Pressure Compensator with Load Sense XD5 s standard Pressure Comp Load Sense control can be adapted to run in the following ways Pr...

Страница 9: ...control will de stroke the pump until Pcomp Po Please note that the compensator will de stroke the pump until Qo 0 if Po continues to exceed Pcomp 6 1 1 2 How to Adjust The Pressure Compensator is ad...

Страница 10: ...oss the restriction in the system is always equal to Pls Flow is proportional to the restriction area size and the pressure differential If the restriction increases or decreases the Control will chan...

Страница 11: ...0 ms Recovery Time 80 ms 6 1 2 4 Bleed Down Orifice Option P 1NN B Option An optional bleed orifice can be installed to increase load sense stability The bleed orifice is installed in OP9 which is und...

Страница 12: ...ed to the LS RP Port on the Valve Plate as shown in Figure 8 For more information on the circuit please see the circuit diagram in Section 6 1 3 5 Additionally 2 values are chosen and adjusted in the...

Страница 13: ...te 1 4 2021 910003 6 1 3 5 Circuit Diagram OP 16 has a 0 031 in ORIFICE OP 9 is PLUGGED OP 6 is PLUGGED The customer supplied Remote Compensator circuit is plumbed into the LS RP Port The Remote Compe...

Страница 14: ...circuit A flow restriction between the outlet of the pump and the implements like an orifice or a flow control valve A pressure signal from the circuit downstream of the restriction and plumbed into...

Страница 15: ...ensator and Load Sense components The Remote Compensator requires a flowrate of approximately 0 25 GPM All internal plugs and orifices use 1 16 NPT plugs and 5 32 internal hex wrenches 6 1 5 Reconfigu...

Страница 16: ...de the MVS option this port will simply be plugged To change the maximum displacement of the pump loosen the locknut and turn the adjuster in or out to reach the desired maximum displacement Turning t...

Страница 17: ...their cases full of hydraulic fluid during operation If a pump is installed with its driveshaft oriented vertically and its mounting flange pointing up an air bubble can be trapped inside case near th...

Страница 18: ...0 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 18 of 31 Issue Date 1 4 2021 910003 7 4 Mounting Flange Lifting Hook and Rotation Designation 7 5 Driveshafts...

Страница 19: ...Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 19 of 31 Issue Date 1 4 2021 910003 7 7 Clearance Dimensions 7 8 Center of Gravity and Dry Weigh...

Страница 20: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 20 of 31 Issue Date 1 4 2021 910003 7 9 Valve Plate Views...

Страница 21: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 21 of 31 Issue Date 1 4 2021 910003 7 10 Tandem Mount Adapters...

Страница 22: ...ponents Replace Loss of Pressure Worn piston pump Inspect components Replace Worn or grooved cylinder barrel and or valve plate mating surfaces Worn piston shoe assemblies or piston bores in cylinder...

Страница 23: ...e pressure must be less than 25 psi 1 7 bar For higher case pressures special shaft seals are required contact our Customer Service Each drain line must be a separate line unrestricted full sized and...

Страница 24: ...een to dry clean and refill case to level mark and install screen Refer to the manufacturer s recommendations Fluid Filling and Starting Recommendations Refer to instruction plate on the unit reservoi...

Страница 25: ...r 4 Hollow Hex Plug 904 2 505 O Ring TS Adapter to Coverplate TS Pump with Coverplate 135 1 505 O Ring Tandem Pump Adapter Valve Plate to Flange 042 1 506 O Ring Tandem Pump Adapter B2 Adapter to Pump...

Страница 26: ...n AS568 O Ring Number Quantity 801 Control Block 1 802 2 SAE Hollow Hex Plug 3 803 Koenig Plug 3 804 Control Spool 2 805 Compensator Seat 1 806 Compensator Spring 1 807 Compensator Bonnet 1 808 O Ring...

Страница 27: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 27 of 31 Issue Date 1 4 2021 910003 10 4 Exploded Drawings...

Страница 28: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 28 of 31 Issue Date 1 4 2021 910003...

Страница 29: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 29 of 31 Issue Date 1 4 2021 910003...

Страница 30: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 30 of 31 Issue Date 1 4 2021 910003...

Страница 31: ...Pump Service Manual XD5 100 A1 Phone 402 727 9700 Website www Oilgear com 905 S Downing Street Fremont NE 68025 Page 31 of 31 Issue Date 1 4 2021 910003...

Отзывы: