Pump Service Manual
XD5-100-A1
Phone: (402) 727-9700
Website: www.Oilgear.com
905 S. Downing Street, Fremont, NE 68025
Page 13 of 31
Issue Date: 1/4/2021
910003
6.1.3.5
Circuit Diagram
•
OP 16 has a Ø 0.031 in ORIFICE.
•
OP 9 is PLUGGED.
•
OP 6 is PLUGGED.
•
The customer-supplied Remote
Compensator circuit is plumbed into the
LS/RP Port.
•
The Remote Compensator requires a
flowrate of approximately 0.25 GPM.
All internal plugs and orifices use 1/16 NPT
plugs and 5/32 internal hex wrenches.