18
-
7
) OTHERS
◆
Eeternal output signals
The jack on the back of the machine serves as the detection of
picked screw up, which shall be used with external screw counters.
[Function]: When picked screw up : signal high (ON) approx. 0.2sec
Incoming current: shall be limited to less than 100mA
**CAUTION: Additional resistor is required on
external circuit for regulating current **
[Capacity]: Max DC current: 100mA
External supply voltage: 5 ~24VDC (Max: 27VDC)
[caution]: Please use the plug type of φ3.5-3conductor
miniature jack.
Recommended type:
Marushin Electric Mfg.Co.,Ltd.
MP-019LC (Straight type)
MP-012LN (Right angle type)
Recommended connector cable:
Marushin Electric Mfg.Co.,Ltd.
MC-35ST (
Straight type)
MC-35STL
(Right angle type)
Example of connection
Inseide of the feeder
Outseide of the feeder
High voltage
Low voltage
MJ-352W-O
Signal output jack