background image

APPENDIX A  STANDARD CALIBRATION 

 

 

Ohaus Corporation  www.ohaus.com 

A-2 

Traveler™ Series Service Manual 

Содержание TA152

Страница 1: ...SERVICE MANUAL Traveler Scales Ohaus Corporation 19A Chapin Road P O Box 2033 Pine Brook NJ 07058 2033 973 377 9000...

Страница 2: ......

Страница 3: ...time of publication but Ohaus Corporation assumes no liability arising from the use or misuse of this material Reproduction of this material is strictly prohibited Material in this manual is subject t...

Страница 4: ......

Страница 5: ......

Страница 6: ...ale 3 1 3 3 Replacing the Load Cell 3 2 3 4 Replacing the Printed Circuit Board and Display 3 2 3 5 Replacing the Auxiliary Display s Printed Circuit Board 3 3 3 6 Setting Removing Legal For Trade Onl...

Страница 7: ...NO TITLE 1 1 Power Connection 1 5 1 2 Battery Installation 1 5 1 3 Transportation Lock on Bottom Housing 1 5 1 4 Displays for Traveler Scout SE Carat Gold Series TAJ and TAG 1 6 1 5 Traveler Display I...

Страница 8: ...mponents Appendix A Standard Calibration Explains procedures for Standard Calibration performed prior to using a scale and after service Appendix B Service Calibration Describes the Service Menu which...

Страница 9: ...ons are not met TABLE 1 1 SPECIFICATIONS FOR TA MODELS Model TA152 TA301 TA302 TA501 TA1501 TA3001 TA5000 Capacity g 150 300 300 500 1500 3000 5000 Readability g 0 01 0 01 0 1 0 1 0 1 0 1 1 Linearity...

Страница 10: ...s Counting Tare range To capacity by subtraction Stabilization Time 3 seconds Operating Temperature Range 50 104 F 10 40 C Operating Humidity Range 30 90 Pan Size mm 100 dia 137 x 140 1 TAJ2001 TAJ400...

Страница 11: ...1 0 1 1 1 Off Center Load d Load Distance 1 1 1 1 1 1 1 1 1 Span Mass g 200 200 200 300 300 2000 2000 3000 3000 Linearity Masses g 100 200 200 300 200 400 300 600 300 600 2000 3000 2000 4000 3000 6000...

Страница 12: ...off after no activity is detected for 4 minutes Figure 1 2 Battery installation Before operating the scale check that the Transportation Lock is in the unlock position Otherwise the scale will not be...

Страница 13: ...Long Press Turn scale Off On Zero Off Yes Menu function Yes Used to accept the currently displayed setting Primary function Short Press Send the current display value to serial port if installed Print...

Страница 14: ...All segments will appear briefly followed by a software revision number and then 0 00g Allow 20 minutes warm up time The scale should be calibrated before use See Appendix A 1 5 4 Power OFF To turn th...

Страница 15: ...PC Off Off Hold Off Totalize Off Spec Gr Off C Off End Yes Print Stable Off APrint Off End Yes RS232 ON OFF on Baud 2400 Bits Parity 7 none Handshake none End Yes USB ON OFF on Baud 2400 Bits Parity 7...

Страница 16: ...Figure 1 7 2 Connect the cable to an RS232 port on the computer printer or other device 3 Set the communications parameters to match on both devices 1 6 2 RS232 Commands All communication is accomplis...

Страница 17: ...calibration L Initiate Linearity calibration 0M Gram mode 1M Ounce mode 2M Troy ounce mode 3M Pennyweight mode 4M Parts counting mode 5M Pound Mode 6M Newton 7M Kg 8M Lb oz 9M esc ddddaaaW Write word...

Страница 18: ...problem proceed to the next remedy Before attempting to repair the balance read all chapters of this manual to be familiar with the balance components and operation 2 2 1 Diagnosis 1 Isolate and iden...

Страница 19: ...on weight Slide the pin to the unlocked position Slide switch to the unlocked position Err 1 Invalid checksum data Cycle scale off on See Appendix C to restore data Replace PCB Err 2 Overload or under...

Страница 20: ...ide of the scale using a damp cloth with warm water CAUTION DO NOT USE CHEMICAL CLEANERS OR SOLVENTS OF ANY TYPE SOME CLEANERS ARE ABRASIVE AND MAY AFFECT THE SCALE S FINISH 3 Check the Power Cord for...

Страница 21: ...sition 7 When installing the new Load Cell insert the screws to secure the Load Cell to the Bottom Housing before reconnecting the wires to the PC Board While holding the Load Cell with your hand turn...

Страница 22: ...ied by local weights and measures or approval agency by inserting a seal cable between the red hook on the Calibration Lock Tab and its white counterpart next to the locked position Follow these steps...

Страница 23: ...CHAPTER 3 MAINTENANCE PROCEDURES Ohaus Corporation www ohaus com 3 4 Traveler Series Service Manual...

Страница 24: ...dapter to the scale power receptacle located on the bottom of the scale or install four alkaline AA LR6 batteries 2 Plug the Power Cord into a suitable power source 4 3 Segment Display Test Turn the s...

Страница 25: ...et Up Enter the menu and set the instrument to display the same units as the performance specifications Usually kg g or mg the default is g TEST PROCEDURE 1 Zero the instrument 2 Using a test mass app...

Страница 26: ...________ 6 Calculate the Delta for each reading and record in the work sheet Delta Reading Mean 7 Calculate the Delta x Delta for each reading and record in worksheet 8 Add the ten Delta x Delta value...

Страница 27: ...way between the center and the edge to the front of the Pan Note any differences in the displayed weight reading 4 Repeat the test for the back left and right position of the Pan 5 Maximum allowable c...

Страница 28: ...ove the weight to point D and record the reading 7 If the reading at point A is negative file at points 1 and 4 AT AN ANGLE 8 If the reading at point B is negative file at points 1 and 2 STRAIGHT ACRO...

Страница 29: ...000 1000 Load 1 200 300 1000 1000 1000 4000 Load 2 400 600 2000 2000 2500 4000 Load 3 500 1000 2500 3000 4000 5000 NOTE All masses are nominal values Be certain to use the same reference mass througho...

Страница 30: ...ome shaped Draft Shield 3 Section 5 3 Traveler Scales with No Draft Shield NOTE In all cases where a part is replaced the balance must be thoroughly checked after the replacement is made The balance M...

Страница 31: ...LISTS DIAGRAMS 5 1 TRAVELER SCALES WITH SQUARE DRAFT SHIELD HOUSING PARTS Figure 5 1 Traveler Scales with Square Draft Shield Housing Internal Parts Ohaus Corporation www ohaus com 5 2 Traveler Series...

Страница 32: ...omplete 2a Pan 120mm 3a Pan Support 120mm 2a Pan Square 3a Pan Support Square 5 Function Label 6 Housing Top Bottom 7 Load Cell 8 Hardware Kit 9 PCB Main 10 Battery Cover with Weigh Below Hook 11 Inte...

Страница 33: ...PARTS LISTS DIAGRAMS 5 2 TRAVELER SCALES WITH ROUND DRAFT SHIELD HOUSING PARTS Figure 5 2 Traveler Scales with Round Draft Shield Housing Parts Ohaus Corporation www ohaus com 5 4 Traveler Series Serv...

Страница 34: ...HOUSING PARTS Drawing Item Description 1 Draft Shield Round 2 Pan 100mm 3 Pan Support 100mm 4 Level Bubble 5 Function Label 6 Housing Top Bottom 7 Load Cell 8 Hardware Kit 9 PCB Main 10 Cover Battery...

Страница 35: ...5 PARTS LISTS DIAGRAMS 5 3 TRAVELER SCALES WITH NO DRAFT SHIELD HOUSING PARTS Figure 5 4 Traveler Scales with No Draft Shield Housing Parts Ohaus Corporation www ohaus com 5 6 Traveler Series Service...

Страница 36: ...SHIELD HOUSING PARTS Drawing Item Description 2 Pan Square 3 Pan Support Square 4 Level Bubble 5 Function Label 6 Housing Top Bottom 7 Load Cell 8 Hardware Kit 9 PCB Main 10 Battery Cover w Weigh Bel...

Страница 37: ...CHAPTER 5 PARTS LISTS DIAGRAMS Ohaus Corporation www ohaus com 5 8 Traveler Series Service Manual...

Страница 38: ...ess as it will cause the process to fail 1 Press and hold the ENTER Cal button until CAL appears Cal 2 Press Yes CAL appears followed by a flashing C while a zero reading is stored C 3 The specified c...

Страница 39: ...APPENDIX A STANDARD CALIBRATION Ohaus Corporation www ohaus com A 2 Traveler Series Service Manual...

Страница 40: ...e Ramp value should be between 20 and 60 The actual value is not as important as how it changes It should increase as the weight on the scale is increased And the ramp display should remain constant w...

Страница 41: ...e mid point value is acquired the display shows the second calibration point value 400 Pressing Yes after placing the prompted weight accepts the linearity full capacity weight The display shows C whi...

Страница 42: ...An The display shows C while the scale acquires the zero value C The specified maximum mass weight flashes Place the indicated weight in the center of the Pan 200 Pressing Yes after placing the prompt...

Страница 43: ...APPENDIX B THE SERVICE MENU Ohaus Corporation www ohaus com B 4 Traveler Series Service Manual...

Страница 44: ...Hardware and Software Setup 1 First check that the scale s A Off feature under the SETUP menu is set to OFF If this setting is left ON the scale will shut off during configuration 2 Install the RS232...

Страница 45: ...t match click the arrow next to the parameter and select the correct value See Figure C 2 7 Click the Test Command tab to test the communications See Figure C 3 Figure C 3 Config Tool s Test Command s...

Страница 46: ...ox A and click OK D When the OK button highlights again click Update F Turn the scale off and then back on to save the data A B C D G Figure C 4 The Config Tool s Configuration Screen E F 3 If the Loa...

Страница 47: ...APPENDIX C SOFTWARE SERVICE TOOL INSTRUCTIONS Ohaus Corporation www ohaus com C 4 Traveler Series Service Manual...

Страница 48: ......

Страница 49: ...80251719 P N 80251719 SERVICE MANUAL TRAVELER SERIES SCALES...

Отзывы: