background image

EN-20 

                      RE Series 

 

 

8.3

 

Compliance 

Compliance to the following standards is indicated by the corresponding mark on the product. 

Marking Standard 

 

This product conforms to the EMC directive 2004/108/EC, the Low Voltage Directive 
2006/95/EC and the Non-automatic Weighing Instruments Directive 90/384/EEC.  
The complete Declaration of Conformity is available from Ohaus Corporation. 

 

UL60950-1: 2003 

 

EC Emissions Note 

This device complies with EN61326/CISPR 11 Class B Group 1. 

 

 

Disposal 

In conformance with the European Directive 2002/96/EC on Waste Electrical and 
Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. 
This also applies to countries outside the EU, per their specific requirements. 
 
Please dispose of this product in accordance with local regulations at the collecting 
point specified for electrical and electronic equipment. 
 
If you have any questions, please contact the responsible authority or the distributor 
from which you purchased this device. 
 
Should this device be passed on to other parties (for private or professional use), the 
content of this regulation must also be related. 
 
Thank you for your contribution to environmental protection. 
 
For disposal instructions in Europe, refer to www.ohaus.com/weee. 

 

FCC Note 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment.  This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications.  Operation of this 
equipment in a residential area is likely to cause harmful interference, in which case the user will be 
required to correct the interference at their own expense. 
 

Industry Canada Note 

This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 
 

ISO 9001 Registration 

In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau 
Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant 
with the ISO 9001 standard’s requirements.  On May 15, 2003, Ohaus Corporation, USA, was re-
registered to the ISO 9001:2000 standard. 

Содержание RE series

Страница 1: ...RE Series Price Computing Scale RE C with Tower Model RE Model 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ......

Страница 3: ...Manual Pushbutton Tare 7 4 5 Pre set Keyboard Tare 7 4 6 Weighing and Pricing 8 4 7 Hold Function 8 4 8 Pre pack Weighing Function 8 4 9 PLU Function Price Lookup 9 4 10 By Count Function 10 4 11 Accu...

Страница 4: ...ed accessories and peripherals as available Operate the scale only under ambient conditions specified in these instructions Service should be performed by authorized personnel only 2 INSTALLATION 2 1...

Страница 5: ...AC Power Verify that the intended AC power source matches the AC adapter rating Connect the adapter to the power receptacle underneath and to the right of the scale then plug the AC adapter into a pro...

Страница 6: ...attery Power Saving Feature When powered on batteries the scale will enter sleep mode Weight display will show SLEEP and Unit Price and Total Price displays will be blank after the pre set minutes of...

Страница 7: ...D FUNCTIONS 3 1 Control Panel 3 2 Customer Display 1 Weight display 2 Unit Price display 3 Total Price display 4 Weights Measures marking 5 Leveling Indicator 6 Memory Keys Pull out Tab 7 Numeric Keyp...

Страница 8: ...ulation memory Activates the By Count operation and calculates the price of the item Stores or recalls a PLU In SETUP Mode ends the setup mode Holds the displayed Total Price when the item is removed...

Страница 9: ...15 seconds of inactivity and reactivates with a key press or item placed on the pan 4 3 Zero Operation Press 0 to zero the displayed weight the weight must be stable and within 2 of the scale capacit...

Страница 10: ...ice display The Unit Price and Total Price values are cleared automatically when the item is removed from the pan Unit Price will be retained if the scale is in Pre pack Mode see Section 4 8 4 7 Hold...

Страница 11: ...2 Enter the PLU number with the pre stored data then press PLU The corresponding Unit Price Tare value will be displayed 4 9 1 3 Recalling a PLU with auto PLU search function off Sec 5 2 Press PLU the...

Страница 12: ...tion is used as reference to calculate the price of non weighing items e g the price for 36 pieces when 3 pieces cost a total of 1 50 1 Enter the deal quantity 1 99 e g 3 then press X The X annunciato...

Страница 13: ...mode accordingly press 1 2 successively to price in per lb 1 2 annunciator will turn on per lb 1 4 annunciator will turn on return to normal Unit Price mode To enable Fractional Pricing in the Servic...

Страница 14: ...2 Sleep mode after 5 min Auto off disabled 3 Sleep mode after 5 min Auto off after 30 min 4 Sleep mode after 15 min Auto off disabled 5 Sleep mode after 15 min Auto off after 30 min Step 3 Automatic c...

Страница 15: ...s the switch inside the access hole A narrow screwdriver may be inserted through the hole to press the switch Note When accessing the bottom of the scale avoid placing the scale upside down on the pan...

Страница 16: ...o Ensure the pan is empty and the scale stable Press FIX to initiate countdown sequence 5 0 Countdown The countdown will repeat if the scale is not stable during this process Add20 2 3 calibration poi...

Страница 17: ...ving authorities the scale may be sealed in the following manner 6 2 1 Wire Sealing 1 Install the 2 cross drilled sealing screws securely as illustrated below Run the wire into the holes then apply th...

Страница 18: ...rgent DO NOT use acids alkalis strong solvents or abrasive cleaning agents Inspect the scale regularly Ensure that the housing pan and sub platform are clean and free from foreign material DO NOT allo...

Страница 19: ...roper calibration weights Weight display Weight exceeds power on zero range Remove excess weight from the pan during power on Weight display Overload condition Reduce the load on the pan Total Price d...

Страница 20: ...e Accumulation Keyboard Numeric 32 key tactile membrane switch with key press beeper Span Calibration 2 3 and full scale capacity Tare Range To full capacity by subtraction Zero Range At power on 10 k...

Страница 21: ...RE Series EN 19 8 2 Drawings Memory Keys Pull out Tab Template 13 6 345 mm 13 5 342 mm 17 432 mm 4 5 115 mm 16 7 423 mm 15 2 385 mm 9 5 242 mm 9 5 242 mm 14 356 mm 14 5 342 mm 13 6 345 mm 4 5 115 mm...

Страница 22: ...lated Thank you for your contribution to environmental protection For disposal instructions in Europe refer to www ohaus com weee FCC Note This equipment has been tested and found to comply with the l...

Страница 23: ...n damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohau...

Страница 24: ...80252577 P N 80252577 2008 Ohaus Corporation all rights reserved Printed in China Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Отзывы: