background image

Officine Gullo

2

3

Officine Gullo

TABLE OF CONTENTS

WARNINGS AND SAFETY INSTRUCTIONS .............................................................................4

INSTALLATION MANUAL

ELECTRICAL  SCHEME ..........................................................................................................11
INSTALLATION INSTRUCTIONS ..............................................................................................13
INSTALLATION’S MANUAL ....................................................................................................13
GAS PRESSURE REGULATOR ..................................................................................................13
GAS CONNECTIONS  ........................................................................................................15
TECHNICAL ELECTRICAL DATA TABLE ......................................................................................16
TECHNICAL GAS DATA TABLE ...............................................................................................16
INSTALLATION .....................................................................................................................17
VENTILATION ......................................................................................................................17
IMPORTANT  .......................................................................................................................17
PIPE FOR GAS CONNECTION ..............................................................................................17
CHECKING HEAT OUTPUT ...................................................................................................18
ADJUSTMENTS IN MAIN BURNERS ........................................................................................19
BURNERS TECHNICAL DATA TABLE & ADJUSTMENT VALUES .......................................................19
RULES FOR CONVERTING AND INSTALLING FOR  OTHER TYPES OF GAS ...................................20
REPLACING THE NOZZLE FOR THE BURNERS ..........................................................................20
DECLARATION OF COMPLIANCE ..........................................................................................20
ELECTRIC CONNECTION .....................................................................................................20

USER MANUAL

INSTRUCTIONS FOR USE .....................................................................................................22
LIGHTING AND ADJUSTING THE BURNERS .............................................................................22
TURNING ON AND ADJUSTING THE ELECTRIC OVEN .............................................................22
CARE AND CLEANING INSTRUCTIONS .................................................................................23
WHAT TO DO IN THE EVENT OF A BREAKDOWN ..................................................................24

Содержание GES8MPU

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND USE GES8MPU GAS RANGE WITH ELECTRIC OVEN FOR RESIDENTIAL AND PROFESSIONAL USE...

Страница 2: ...Officine Gullo 2...

Страница 3: ...N 17 IMPORTANT 17 PIPE FOR GAS CONNECTION 17 CHECKING HEAT OUTPUT 18 ADJUSTMENTS IN MAIN BURNERS 19 BURNERS TECHNICAL DATA TABLE ADJUSTMENT VALUES 19 RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPE...

Страница 4: ...r its intended purpose as described in this manual To ensure proper and safe operation Appliance must be properly installed and grounded by a qualified technician DO NOT attempt to adjust repair servi...

Страница 5: ...E OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND C...

Страница 6: ...c shock If the appliance is defective immediately turn the appliance off and discontinue use Disconnect the range from the gas and power supply and contact the assistance If the range is installed beh...

Страница 7: ...urface cooking operation unattended especially when using a high heat setting or when deep fat frying Boilovers cause smoking and greasy spillovers may ignite Clean up greasy spills as soon as possibl...

Страница 8: ...heet When using an electrical appliance e g a hand mixer near the cooktop make sure that the power cable does not come into contact with the hot cooktop The cable s insulation could become damaged Coo...

Страница 9: ...ching or cleaning them DO NOT touch the burner grates or surrounding areas until they have had sufficient time to cool Clean appliance with caution Use care to avoid steam burns if a wet sponge or clo...

Страница 10: ...o Backofen Bypass By pass four Oven by pass By pass horno FIG F PC GP CF GP FUOCHI FLAMME FEUX COOKING RINGS FUEGOS 562047300M00P00 1 2 3 4 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Inj...

Страница 11: ...codes In the absence of local codes the installation must conform to the latest level of the National Electric Code ANSI NFPA 70 If the electrical supply is not turned on or is interrupted the applian...

Страница 12: ...ion box Tablero de bornes 4 Resistenza Widerstand R sistance Element Resistencia 5 Spia bianca wei e Kontroll Leuchte T moin blanc White light Luz indicadora blanca 6 Spia verde gr ne Kontroll Leuchte...

Страница 13: ...mproper or incorrect installation alterations maintenance or use of the appliance as in all the other cases considered in the items of our sales conditions GAS PRESSURE REGULATOR Must be installed Eac...

Страница 14: ...gas regulator 1 Unscrew the hex nut 2 Choose the proper gas regulator NAT natural gas LP LPG NAT set for natural gas LP set for LPG 3 Insert the gas regulator in the chosen side in the hex cap 4 Put...

Страница 15: ...for a variety of reasons Under no circumstances should the factory supplied regulator be removed or by passed 8 The factory supplied pressure regulator will withstand an input pressure of PSI 13 iwc...

Страница 16: ...le mm GES8MPU 80x70x90h 5 21 74 110 110V 50 60 Hz 3 x 2 5 MODEL DIMENSIONS cm NOMINAL BURNER CAPACITY TOT NOM CAPACITY Gas coupling NPT Nr Open ring 11 942 BTU h Nr Open ring 18 767 BTU h Nr Open ring...

Страница 17: ...with other appliances of our production It is necessary to observe a minimum distance of 4 10 cm from the appliance to prevent contact with walls of inflammable material adequate measures must also b...

Страница 18: ...Figure A Read the pressure with a gauge inserted in the relative pressure outlet see figure A Remove the hermetically closed screw and connect the gauge pipe After reading put back the screw tightenin...

Страница 19: ...lues note that for LPG the screw position should be closed GAS A Natural gas pressure at the outlet of the regulator 10 mbar 4 inch water GAS E Propane gas pressure at the outlet of the regulator 24 9...

Страница 20: ...ilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation maintenance or use of the appliance an...

Страница 21: ...r than the others so that if the cable blocker should break for any reason it will disconnect after the hot wires The installation of this appliance must conform with all applicable local codes In the...

Страница 22: ...JUSTING THE ELECTRIC OVEN Before turning the oven on make sure the oven racks are in the desired position Turn the control knob to the right and set the temperature wanted To turn the oven on turn the...

Страница 23: ...ce metal polishes are abrasive and it will take away some of the chrome plating with each use Cleaning burnished brass surfaces The antiquing finish of the surface Burnished Brass is the result of nat...

Страница 24: ...fact our brushed stainless steel finish is accomplished by millions of little scratches But in the event that you have a deep scratch that you want to care for the surfaces can always be re brushed u...

Страница 25: ...25 Officine Gullo...

Страница 26: ...Officine Gullo 26...

Страница 27: ...27 Officine Gullo...

Страница 28: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM us V 2 7 12 20...