Officine Gullo
16
TECHNICAL GAS DATA TABLE
TECHNICAL ELECTRICAL DATA TABLE
MODEL
Dimensions
cm
Tot
kW
Max.
Assorb. A
Power supply
Power supply
cable mm²
GES8MPU
80x70x90h
5
21,74
110+110V
50/60 Hz
3 x 2,5
MODEL
DIMENSIONS
cm
NOMINAL BURNER CAPACITY
TOT.NOM.
CAPACITY
Gas
coupling
NPT
Nr. Open ring
11,942
BTU/h
Nr. Open ring
18,767
BTU/h
Nr. Open ring
25,591
BTU/h
Gas
BTU/h
GES8MPU
80x70x90h
1
2
1
75,067
R1/2GM
3/4GM(1007)
The machine is supplied with pressure regulator separately (in 3/4 NPT F)
17
Officine Gullo
INSTALLATION
The appliance must be installed in accordance with the ANS Z83.11a CSA 1.8a-(2001) Food Service Equipment,
•
The operations for installing, conversions for use with other types of gas and starting up must be done only
by qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply
with the norms in force in the Country in which the installation is carried out; above all, the appliance must
be installed in a well ventilated room, preferably under an extractor hood, so as to ensure the complete
extraction of gas emissions which are formed during combustion. The air necessary for combustion is 70.6
CbtF /h per 3412BTu's (2m3 /h per kW) of power installed.
VENTILATION
Proper ventilation is highly important for good operation. This appliance must be installed under a properly designed
canopy hood. A strong exhaust fan can create a vacuum in the room. For proper air balance, work with your
contactor to properly size the air inlet.
IMPORTANT
ALL GAS BURNERS NEED SUFFICIENT AIR TO OPERATE AND LARGE OBJECTS SHOULD NOT BE PLACED IN
FRONT OF THIS APPLIANCE WHICH WOULD OBSTRUCT THE AIR FLOW THROUGH THE FRONT. OBJECTS
SHOULD NOT BE PLACED ON THE REAR BACKGUARD WHILE IN USE.
THIS COULD OBSTRUCT THE VENTING SYSTEM OF THE OVEN’S FLUE PRODUCT
S.
Ensure that the air outlets in the place of work are sufficient to guarantee the necessary air exchange.The appliance
may be installed as a single element or in series with other appliances of our production. It is necessary to observe a
minimum distance of 4" (10 cm) from the appliance to prevent contact with walls of inflammable material; adequate
measures must also be taken to ensure thermal insulation of inflammable parts, such as the installation of a protection
against radiation; particular attention must be paid in installing the appliances adequately and safely. The feet are
adjustable in height so that differences in level can be avoided.
The machine must be place in conditions of optimal ventilation: the area for the combustion of the item comes captured
from the bottom of the same one.
The minimal necessary area for the combustion is given from the minimal height of the feet mounted on the machine,
therefore the machine cannot be installed without the adjustable feet.
In case of wood cabinetry placed on the side of the range, the cabinetry has to be mounted on top of feet in order
to grant a correct ventilation to the machine.
PIPE FOR GAS CONNECTION
The gas connection must be done with steel pipes, or otherwise with flexible steel pipes in compliance with the
national norms, if any exist. Each appliance must be provided with a cut-off cock for rapid interruption of the gas
supply. Once the appliance has been installed, it is necessary to check for gas leaks for the pipe fittings; do not
use a flame for this purpose but a non-corrosive substance such as soapy water or foamy substances as contained
in leak-finder sprays. All our appliances undergo careful testing: the type of gas, the operating pressure and the
category are indicated on the data plate.
NB:
The year of the appliance manufacture is shown in item “N” on the data plate. The first two numbers (e.g. 08...)
represent the year of manufacture.