TURNING OFF THE APPLIANCE

Push and turn the knob into position “0”. This command blocks the gas supply to both the 
main burner and the pilot burner. To relight the appliance, it is necessary to turn the knob 
again into position and press the button.

EMPTYNG THE TUB MOD. CVS...

The user should be equipped with a suitable container for the 
drained water. Insert the outlet pipe as shown on the drawing 
and place the container in position. Push the safety device (A) 
upwards and move lever (B) to the symbol 

   

 .

Important: 

pay attention to the clearance between the appliance 

and the edges of the stands.

EMPTYNG THE TUB CVCS....

To carry out this operation, it is necessary to open the outlet tap (lever in vertical position) which 
can only be reached through the cabinet door situated below the appliance.

SAFETY THERMOSTAT MOD.CVS…

The appliance is provided with a safety thermostat which interrupts the gas flow if the temperature 

goes above the maximum set value. When the safety device intervenes, both the main burner and 
pilot burner go out.
If this happens, it is possible to restart by pressing down fully the red thermostat button after 
having removed the control panel. If the problem occurs again, call in the after sales assistance.

ANOMALIES

If the probe does not detect the presence of water in the tank for more than 15 sec. the system 

disables the heating element: the alarm is indicated by a flashing red light.

When the probe returns to detect the presence of water, the heating element is activated and the 
red light is turned off.

NOTE: the filling phase is monitored by the system through the TIME-OUT.

OBSERVATIONS AND ADVICE

Always keep the water level checked.

ATTENTION! Do not start up the appliance without water.

Use the appliance only under surveillance.

   

Содержание CVCS4G

Страница 1: ...INSTRUCTIONS for installation and use PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE CVCS4G CVCS6G CVS4G CVS6G...

Страница 2: ...appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and close...

Страница 3: ...G A 65 635 700 28 79 511 105 35 200 50 285 17 302 25 75 37 377 33 40 400 800 1200 1600 B C A 635 700 635 700 28 511 105 35 200 50 285 17 302 25 75 335 40 40 207 400 800 1200 1600 B C A 635 700 A Data...

Страница 4: ...4 Officine Gullo CVSC4G A Data Plate C Gas Connection ISO 7 1 R1 2GM D Water connection R 1 2GM E Water drainage R 1GF FIG B...

Страница 5: ...5 Officine Gullo CVSC6G A Data Plate C Gas Connection ISO 7 1 R1 2GM D Water connection R 1 2GM E Water drainage R 1GF FIG B2...

Страница 6: ...6 Officine Gullo FIG C Piezoelectric device Bypass FIG D 2 3 4 1 1 H Injector 1 Bride 2 Pilot 3 Thermocouple 4 Spark plug...

Страница 7: ...7 Officine Gullo FIG E WATER FILLING TAP...

Страница 8: ...gaz Gas solenoid valve Electrov lvula gas 5 Pulsante accensione bruciatori Druckknopf Brennerz ndung Poussoir allumage br leurs Push button starting burner Pulsador encendido quemador 6 Interruttore b...

Страница 9: ...E 15 SPARE PARTS 15 WATER SUPPLY CHARACTERISTICS 15 WATER CONNECTION AND DRAINAGE 15 STARTING UP 16 LIGHTING AND ADJUSTING THE MAIN BURNER MOD CVS 16 OPERATION MOD CVC 16 TURNING OFF THE APPLIANCE 17...

Страница 10: ...sions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation maintenance or use of the appliance and alterations as in all the othe...

Страница 11: ...latest editions concerned The installation transformation and repair of appliances for professional kitchens as well as removal due to malfunction and the supply of gas may be made only by means of a...

Страница 12: ...te installations not compliant with the instructions CHECKING HEAT OUTPUT The appliances must be checked in such a way as to verify that the heat output is correct The heat output thermal power is ind...

Страница 13: ...urner 9 kW min 3 7 kW Burner Injector 1 100 mm Min output adjustment 1 100 mm Pilot Injector Consumption Primary air h mm 150 85 19 kg h 0 710 20 150 85 19 kg h 0 699 20 230 adjustable 35 m st h 0 952...

Страница 14: ...ew the nozzle and substitute it with the right one see the Technical Data table The main burner does not require any regulation of the primary air SUBSTITUTING THE NOZZLE IN THE PILOT BURNER The flame...

Страница 15: ...and washing up liquid rinsed thoroughly and filled with water up to the level indicated by the mark on the back of the water tub DO NOT START UP THE APPLIANCE WITH THE WATER TUB EMPTY WATER SUPPLY CHA...

Страница 16: ...w second and then let it go this lights the pilot If the flame goes out you have to repeat the procedure By turning the knob round to the position the burner is at maximum By turning the knob round to...

Страница 17: ...uated below the appliance SAFETY THERMOSTAT MOD CVS Theapplianceisprovidedwithasafetythermostatwhichinterruptsthegasflowifthetemperature goes above the maximum set value When the safety device interve...

Страница 18: ...sed to obtain the special burnishing effect on the burnished brass details in order to avoid spoiling the beauty of the brass with an artificial patina The antique finish of the surface is the result...

Страница 19: ...neutral detergent and where necessary a soft possibly micro fiber cloth Do not use abrasive pads or any other chemical products CLEANING BRUSHED STEEL SURFACES All the brushed steel surfaces should b...

Страница 20: ...no hood as an alternative an air extractor connected directly to the outside is acceptable Forced Discharge Fig 2 In the event of forced discharge The gas supply to the appliance must be directly int...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...WWW OFFICINEGULLO COM V 2 1 9 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com en INTERNATIONAL...

Отзывы: