Before using the appliance, it is necessary to clean it carefully, especially the water tub 
(see paragraph “cleaning and care”).
Check the connection of the appliance and start it up following the instructions, 
“Instructions for use”.

Attention!

 - Use the appliance only under surveillance.

WATER FILLING

Check that the drainage tap is in the “off” position.
Fill the tub with water up to the level indicated by the mark.

LIGHTING AND ADJUSTING THE MAIN BURNER - MOD. CV...

On the front panel, above each knob, the burner it corresponds to 
is indicated by the index  

   

To light, turn the knob to the left from position “0” to the

   

symbol (see figure);

keep it pushed down and press the button with the symbol until 
the gas lights 
Keep the knob pressed a few second and then let it go, this lights 
the pilot.

If the flame goes out you have to repeat the procedure.

By turning the knob round to the   

   

   position the burner is at maximum.

By turning the knob round to the   

   

   position the burner is at minimum.

To switch off, move the knob back into position " 0".

OPERATION MOD. CVC…

1) When powering the green on-off device, the red light flashes briefly for about ½ 

second.

2) In the absence of water in the tank the red light keeps flashing.

3) Turn on the tap to load the tank to the desired level, which must be higher than the 
minimum level probe and do not exceed the maximum level, which is marked on the tank 

by the symbol (―)

4) Turn the gas knob to the 

   

 position and hold it down.

At the same time, press the 

 button to turn on the gas to light the 

pilot.

5) Turn the gas knob to the

   

 position: The burner will remain off 

until the water reaches the minimum level probe.
6) To set the burner to the minimum, turn the gas knob to the 
position 

   

Содержание CVCS4G

Страница 1: ...INSTRUCTIONS for installation and use PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE CVCS4G CVCS6G CVS4G CVS6G...

Страница 2: ...appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and close...

Страница 3: ...G A 65 635 700 28 79 511 105 35 200 50 285 17 302 25 75 37 377 33 40 400 800 1200 1600 B C A 635 700 635 700 28 511 105 35 200 50 285 17 302 25 75 335 40 40 207 400 800 1200 1600 B C A 635 700 A Data...

Страница 4: ...4 Officine Gullo CVSC4G A Data Plate C Gas Connection ISO 7 1 R1 2GM D Water connection R 1 2GM E Water drainage R 1GF FIG B...

Страница 5: ...5 Officine Gullo CVSC6G A Data Plate C Gas Connection ISO 7 1 R1 2GM D Water connection R 1 2GM E Water drainage R 1GF FIG B2...

Страница 6: ...6 Officine Gullo FIG C Piezoelectric device Bypass FIG D 2 3 4 1 1 H Injector 1 Bride 2 Pilot 3 Thermocouple 4 Spark plug...

Страница 7: ...7 Officine Gullo FIG E WATER FILLING TAP...

Страница 8: ...gaz Gas solenoid valve Electrov lvula gas 5 Pulsante accensione bruciatori Druckknopf Brennerz ndung Poussoir allumage br leurs Push button starting burner Pulsador encendido quemador 6 Interruttore b...

Страница 9: ...E 15 SPARE PARTS 15 WATER SUPPLY CHARACTERISTICS 15 WATER CONNECTION AND DRAINAGE 15 STARTING UP 16 LIGHTING AND ADJUSTING THE MAIN BURNER MOD CVS 16 OPERATION MOD CVC 16 TURNING OFF THE APPLIANCE 17...

Страница 10: ...sions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation maintenance or use of the appliance and alterations as in all the othe...

Страница 11: ...latest editions concerned The installation transformation and repair of appliances for professional kitchens as well as removal due to malfunction and the supply of gas may be made only by means of a...

Страница 12: ...te installations not compliant with the instructions CHECKING HEAT OUTPUT The appliances must be checked in such a way as to verify that the heat output is correct The heat output thermal power is ind...

Страница 13: ...urner 9 kW min 3 7 kW Burner Injector 1 100 mm Min output adjustment 1 100 mm Pilot Injector Consumption Primary air h mm 150 85 19 kg h 0 710 20 150 85 19 kg h 0 699 20 230 adjustable 35 m st h 0 952...

Страница 14: ...ew the nozzle and substitute it with the right one see the Technical Data table The main burner does not require any regulation of the primary air SUBSTITUTING THE NOZZLE IN THE PILOT BURNER The flame...

Страница 15: ...and washing up liquid rinsed thoroughly and filled with water up to the level indicated by the mark on the back of the water tub DO NOT START UP THE APPLIANCE WITH THE WATER TUB EMPTY WATER SUPPLY CHA...

Страница 16: ...w second and then let it go this lights the pilot If the flame goes out you have to repeat the procedure By turning the knob round to the position the burner is at maximum By turning the knob round to...

Страница 17: ...uated below the appliance SAFETY THERMOSTAT MOD CVS Theapplianceisprovidedwithasafetythermostatwhichinterruptsthegasflowifthetemperature goes above the maximum set value When the safety device interve...

Страница 18: ...sed to obtain the special burnishing effect on the burnished brass details in order to avoid spoiling the beauty of the brass with an artificial patina The antique finish of the surface is the result...

Страница 19: ...neutral detergent and where necessary a soft possibly micro fiber cloth Do not use abrasive pads or any other chemical products CLEANING BRUSHED STEEL SURFACES All the brushed steel surfaces should b...

Страница 20: ...no hood as an alternative an air extractor connected directly to the outside is acceptable Forced Discharge Fig 2 In the event of forced discharge The gas supply to the appliance must be directly int...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...WWW OFFICINEGULLO COM V 2 1 9 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com en INTERNATIONAL...

Отзывы: