Clamp pincer CP 10 / CP 20 / CC 20
7 Description of PC software
Issue 06.19
08902961
7-46
The initial calibration closure force for the various devices is factory-set as follows:
•
CP 10 =
Closure force 1000 N
•
CP 20 =
Closure force 3500 N
•
CC 20 =
Closure force 3500 N
Closure force calibration
Closure force calibration is performed with the target value for the closure force, so as to achieve the highest
accuracy by the pincer system.
Five measured closures are performed during the course of the closure force calibration. An average is
calculated from the results of these five measured closures, and this is loaded to the device.
7.5
Firmware menu
New firmware is loaded on the device with the Firmware menu (see chapter 4.4 Updating firmware, p. 4-17).
Fig. 35: Firmware menu