Clamp pincer CP 10 / CP 20 / CC 20
4 PC software & firmware
Issue 06.19
08902961
4-19
INFO
If the “FW update” button is pressed before the device has switched to transfer mode, the “No device found”
advice window is displayed, with information on how to proceed (see below).
5.
Select the new firmware version in the “Open” window and press the “Open” button to confirm the selection.
Fig. 8:
Confirming firmware selection
The selected firmware will now be loaded. After the firmware has been loaded successfully the device switches
on automatically, the loaded firmware is active and the firmware update is now complete.
INFO
The status of the firmware update can be read off from the progress bar for data transmission (Fig. 31/5).
Once the transfer has been successfully completed, th
e message “Data successfully transferred” is displayed.
If the firmware transfer was unsuccessful, the information window “Data not correctly transferred” appears. In
this case, repeat the process.