Installation
44
GA03107_002_A4 - 09/2015 - © Oerlikon Leybold Vacuum
3.5 Connecting the ATEX-Motor
The RUVAC WA pump can also be ordered without a connected motor (see
Ordering Data).
When motor is fitted by the customer, the operator will be responsible for
selecting and operating the motor. Mounting the motor has an influence on
the operation and reliability of various pump components, coupling and
bearings in particular. Not complying with the technical data and installation
information in the following will void CE and ATEX conformity resulting in a
rejection of any warranty claims.
The ATEX category for the outside area can change depending on the type
of motor. Use only such motors which are approved for the respective cat-
egory.
T3 motors of the type Exe have, as standard, different flange and shaft diam-
eters. These motors must be ordered with a reduced diameter (see following
Table).
NOTICE
Specific motor data
WA 251
WA 501
WA 1001
WA 2001
Type
3-ph. motor
3-ph. motor
3-ph. motor
3-ph. motor
Model
1
IM B5
IM B5
IM B5
IM B5
Size
1
80 L
90 L
112 M
132 M
Flange
FF165
FF165
FF215
FF265
Nominal power rating
2
P
kW
1.1
2.2
4
7.5
Outside flange diameter
D1
mm
200
200
250
300
Pitch circle diameter, bolts
D2
mm
165
165
215
265
Screw size
M
-
M10
M10
M12
M12
Number of screws
N
-
4
4
4
4
Centering diameter
2
D3
mm
130
j6
130
j6
180
j6
230
j6
Shaft journal, motor
2
D4
mm
19
j6
24
j6
28
j6
38
k6
Concentricity, shaft journal
3
X1
mm
0.04
0.04
0.04
0.05
Coaxiality, centering flange
3
X2
mm
0.1
0.1
0.1
0.125
Run out, mounting flange
3
X3
mm
0.1
0.1
0.1
0.125
1 Motor in accordance with EN 60034-1, EN 60034-7, DIN 52677 Part 3
2 Three-phase motors with standardised dimensions and power ratings in accordance with EN 50347
3 Concentricity of the shaft journals, coaxiality and run out of the mounting flange in accordance with DIN 42955, see also Fig. 3.5
Содержание RUVAC WA
Страница 67: ...Notes 67 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...
Страница 68: ...68 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Declaration of Conformity ...
Страница 69: ...69 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Incorporation Declaration ...
Страница 71: ...Index 71 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...