ATEX
16
GA03107_002_A4 - 09/2015 - © Oerlikon Leybold Vacuum
Equation (2):
(2)
p
a, max. permissible
≤
p
v
/
k
eff, permissible
≤
∆p
max
/
(k
th
-1)
If k
eff
cannot be reliably determined, here too k
th
must be applied.
Generally the following applies to ATEX applications:
p
E
(cut-in pressure, see Section 4) = p
a, max. permissible
Fitting the Pt 100 Temperature Sensor
∆p
RUVAC WA
p
s
/p
a
p
v
p
a
= p
v
/k
th
S
V
Roots
S
V
backing pump
Pt 100
Fig. 0.1 Temperature measurement with the temperature sensor Pt 100 for T3 operation
with k
th
=
The tip of the Pt 100 temperature sensor (P/N 155 010 - not included in the
delivery) measures the gas temperature in the middle of the RUVAC’s dis-
charge flange (see Fig. 0.1 and 0.2. Depending on the size of the RUVAC
pump respectively its flange, the Pt 100 sensor needs to be fitted at different
positions. The temperature sensor Pt 100 is equipped with three installation
marks (
marks A,B,C
, see Fig. 0.2). According to the information given in the
following table the Pt 100 must be inserted up to the respective mark into the
clamp fitting and secured reliably. In the enclosed installation instructions for
the clamp fitting, the required torque levels are stated. Before installing, the
transport protectors must be removed.
RUVAC WA/WAU
Pt 100
Fig. 0.2 Position of the temperature sensor at the discharge flange of the RUVAC WA/WAU
Motor
Protection tube with
installation marks (A/B/C)
Clamp fitting
Содержание RUVAC WA
Страница 67: ...Notes 67 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...
Страница 68: ...68 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Declaration of Conformity ...
Страница 69: ...69 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Incorporation Declaration ...
Страница 71: ...Index 71 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...