2. SAFETY INSTRUCTIONS 

 
 

2.2.   Placement 
 

Location 
 

 

OCTAVE equipment is designed strictly for use in a dry domestic environment. Do not use it in 
open air or in damp environments! 

 

Never place plants or liquid-filled containers on your amplifier. Take care that objects do not fall 
or  liquids  are  not  spilled  into  the  enclosure.  Should  this  happen,  disconnect  the  mains  plug 
immediately and have your amplifier checked by a qualified service technician. 

 

Condensation may form if the amplifier is taken from a cold environment into a warm one. In this 
case, wait until the amplifier has reached room temperature and is dry before switching it on. 

 

Avoid installing the amplifier close to sources of heat, such as heaters, or anywhere that it may 
be in direct sunlight. 

 

Do not operate your OCTAVE amplifier near flammable materials, gases, or vapors. Avoid areas 
where  there  may  be  heavy  accumulations  of  dust  or  where  the  amplifier  may  be  subject  to 
mechanical vibration. 

 

Place your OCTAVE amplifier on a stable, even surface. 

 

Cover 

Never operate the amplifier without the cover. 

Ventilation 

 

Ensure sufficient air circulation around your amplifier. If you intend to install your equipment in a 
cupboard or a shelf unit, ensure that there is at least a 10 centimeter gap between the ventilation 
slots and the walls all around the amplifier. 

 

To prevent heat accumulation, the back of the cupboard should have ventilation holes. 

 

Do not rest the equipment on a soft surface such as carpet or foam sheeting. 
 

2.3.  Warranty 

OCTAVE can only guarantee the safety, reliability and performance of this unit if modifications and 
repairs are carried out by specialized personnel and if the amplifier is operated in accordance with 
the instructions contained in this manual. 

 
 

 

Содержание HP 700 SE

Страница 1: ...HP 700 SE Owner s Manual English...

Страница 2: ...t from the classic circuit designs has not done the technology any favors Today s loudspeakers and source equipment provide better performance than ever before but also make greater demands on amplifi...

Страница 3: ...4...

Страница 4: ...00 SE in multi channel mode 17 8 Remote control for volume 8 1 Remote control operating elements 19 8 2 Battery replacement 19 9 Tubes 9 1 Line tube layout 20 9 2 Phono tube layout 21 9 3 Control unit...

Страница 5: ...ons 35 12 2 1 HP 700 SE preamplifier dimensions in mm 35 12 2 2 External power supply dimensions in mm 35 12 3 Diagrams 36 12 3 1 HP 700 SE line frequency response 36 12 3 2 FFT interference spectrum...

Страница 6: ...elf OCTAVE tube technology OCTAVE amplifiers are equipped with a proprietary control and monitoring system we call Power Management This is an electronic brain within the amp that regulates and contro...

Страница 7: ...ISION TECHNOLOGY IN THE LINE STAGE The term precision technology stands for a circuit in tube technology that has an extreme bandwidth up to 1 MHz an impressively low output resistance of 130 ohms and...

Страница 8: ...alance control allows channel separated volume adjustment in 1 dB steps This technology eliminates any controller related sound shifts Using 12 position stepped switches the setting is long time stabl...

Страница 9: ...uld also only be replaced by a qualified technician Always replace fuses with ones of the same type and rating If your amplifier requires servicing please ship or take your equipment directly to OCTAV...

Страница 10: ...e your OCTAVE amplifier near flammable materials gases or vapors Avoid areas where there may be heavy accumulations of dust or where the amplifier may be subject to mechanical vibration Place your OCT...

Страница 11: ...before connecting the power cable to the wall socket 5 Check that the volume control is not set at maximum before playing music through the preamplifier and that the function switch 1 is set to the se...

Страница 12: ...s bypassed This setting is intended for multi channel applications with volume control on the multi channel receiver The bypass HT RCA input is separate the bypass function can be switched to an XLR i...

Страница 13: ...o or line input module 8 IN 5 RCA input Line level input for CD tuner etc 9 IN 3 XLR input Balanced line level input for CD DAC etc 10 IN 6 RCA input Line level input for CD tuner etc 11 IN 7 RCA inpu...

Страница 14: ...17 18 OUT 3A OUT 3B Two pairs of XLR outputs for balanced output stages XLR output for balanced power amplifiers 1 ground 2 positive 3 negative ground lift XLR With the ground lift the XLR outputs ca...

Страница 15: ...en the power supply is on During the start up phase the start and muting LEDs illuminate on the preamplifier After the start up phase the start and muting LEDs go out if the mode switch is not set to...

Страница 16: ...nd left on the multi channel source are connected to the bypass input 13 on the HP 700 SE if the multi channel device only has RCA outputs If the multi channel receiver also has balanced outputs for t...

Страница 17: ...g the common volume of the multi channel system has to be set on the multi channel source For the RCA outputs and the balanced XLR output the volume control for the HP 700 SE is then disabled In this...

Страница 18: ...inserting the batteries If the remote control does not work after the batteries are replaced remove the new batteries and wait at least 30 minutes You can then re insert the batteries and the remote...

Страница 19: ...ed when opening the cover and injury through electric shock Before opening the cover switch the device off and unplug the power cord Tube layout line board Tube layout line board V 1 ECC82 12 AU 7 V 2...

Страница 20: ...21 9 TUBES 9 2 Phono tube layout Tube layout phono board German designation International designation V 4 ECC 83 12 AX 7 V 5 ECC 81 12 AT 7 V 6 ECC 88 6922 SV 6N23P SV alternatively 6 DJ 8...

Страница 21: ...V 7 tube Note The control unit cannot be disassembled during tube replacement as it is physically connected to the front 1 Disassemble the shortened cover 2 If your device is equipped with the phono...

Страница 22: ...tubes Straighten any bent pins very carefully by hand if necessary Cleaning tips Cleaning agents and contact cleaners are not recommended for tube sockets Clean dirty sockets with compressed air and...

Страница 23: ...of inputs is insufficient or the inputs IN4 IN8 transformer coupled or IN9 transformer coupled is to be used for sound or technical reasons 10 1 1 Assembling the additional line level input module 1 R...

Страница 24: ...ors of the supplied ribbon cable in the designated slot on the adapter board on the HP 700 SE slots 1 and 2 are equivalent The blade terminal cannot be twisted since it can only be inserted in one pos...

Страница 25: ...entire frequency range with channel matching of at least 0 3 dB The phono RIAA amplifier of the HP 700 SE must always be supplemented with an input module A maximum of two phono input modules can be i...

Страница 26: ...enuated with the switchable subsonic filter The roll cutoff frequency is outside of the audible range at 15 Hz Condition on delivery Subsonic filter on Phono frequency response with and without subson...

Страница 27: ...ing the cover switch off the device and unplug the power cord 1 Loosen the M4 screws on the cover and pull off the cover plate upwards 2 Loosen the 4 Phillips head screws on the corresponding rear cov...

Страница 28: ...ated attenuators originate from high frequency technology Compared to more simple non compensated variants their advantage is that the frequency bandwidth and phase shift are not affected 28 Rotary kn...

Страница 29: ...ally helpful in old muffled and bass weak analog recordings and in new digital productions which sometimes feature a distinct high frequency tending towards sharpness Here corrections of 3 dB truly wo...

Страница 30: ...nsisting of individual resistors The stepped attenuator now senses the connecting points of the resistor ladder The advantages of this solution are obvious thanks to the low tolerance fixed resistors...

Страница 31: ...nd when they are switched on and off audible clicks and pops in the system s loudspeakers may occur Solution The only solution is to use a single power socket board for your entire system and to use a...

Страница 32: ...Gain High 98 dB 38 V Signal to noise ratio Gain Med 104 dB 18 V Signal to noise ratio Gain Low 110 dB 8 V Equivalent noise level 14 nV Hz Frequency range Gain High RCA 10 Hz 200 kHz 0 7 dB 0 7 MHz 6...

Страница 33: ...pend on input module Overall Gain MC Gain Low Pre Out RCA XLR Gain Low 70 dB Med 77 dB High 83 dB MC Gain High Pre Out RCA XLR Gain Low 79 dB Med 86 dB High 92 dB General data Power consumption 35 60...

Страница 34: ...35 12 TECHNICAL DATA 12 2 Dimensions 12 2 1 HP 700 SE preamplifier dimensions in mm 12 2 2 External power supply dimensions in mm...

Страница 35: ...gain of line stage in Gain Low 12 dB Med 18 dB and High 25 5 dB settings 12 3 2 FFT interference spectrum Comparison of the RCA and XLR interference spectrum No mains interference on either of the in...

Страница 36: ...pensated balance pre control exhibits virtually the same frequency response with all settings 12 3 4 Line stage hum and noise level No mains interference can be detected during noise level measurement...

Страница 37: ...38...

Страница 38: ...specifications in pursuit of better OCTAVE logo is a registered trade mark of Andreas Hofmann Copyright byAndreas Hofmann OCTAVEAUDIO T 49 0 7248 3278 ANDREAS HOFMANN F 49 0 7248 3279 REUTAECKERSTR 5...